Textured silicon calorimetric light detector

被引:19
作者
Di Stefano, PCF
Frank, T
Angloher, G
Bruckmayer, M
Cozzini, C
Hauff, D
Pröbst, F
Rutzinger, S
Seidel, W
Stodolsky, L
Schmidt, J
机构
[1] Max Planck Inst Phys & Astrophys, D-80805 Munich, Germany
[2] Inst Solarenergieforsch Hameln Emmerthal, D-31860 Emmerthal, Germany
[3] Inst Phys Nucl, F-69622 Villeurbanne, France
关键词
D O I
10.1063/1.1619196
中图分类号
O59 [应用物理学];
学科分类号
摘要
We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption is compatible with the increase in surface area. For the geometrically thin detectors studied, energy resolution from athermal phonons, dominated by position dependence, is proportional to the surface-to-volume ratio. With the CaWO4 scintillating crystal used as light source, the time constants of the calorimeter should be adapted to the relatively slow light-emission times. (C) 2003 American Institute of Physics.
引用
收藏
页码:6887 / 6891
页数:5
相关论文
共 20 条
[1]   A scintillating bolometer for experiments on double beta decay [J].
Alessandrello, A ;
Bashkirov, V ;
Brofferio, C ;
Bucci, C ;
Camin, DV ;
Cremonesi, O ;
Fiorini, E ;
Gervasio, G ;
Giuliani, A ;
Nucciotti, A ;
Pavan, M ;
Pessina, G ;
Previtali, E ;
Zanotti, L .
PHYSICS LETTERS B, 1998, 420 (1-2) :109-113
[2]  
Arndt R. A., 1975, 11th IEEE Photovoltaic Specialists Conference, P40
[3]   Status of the EDELWEISS Experiment [J].
Berge, L ;
Berkes, I ;
Chambon, B ;
Chapellier, M ;
Chardin, G ;
Charvin, P ;
De Jesus, M ;
Di Stefano, P ;
Drain, D ;
Dumoulin, L ;
Goldbach, C ;
Juillard, A ;
L'Hote, D ;
Marnieros, S ;
Miramonti, L ;
Mosca, L ;
Navick, XF ;
Nollez, G ;
Pari, P ;
Pastor, C ;
Pecourt, S ;
Tourbot, R ;
Yvon, D .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 70 :69-73
[4]   Alpha/gamma discrimination with a CaF2(Eu) target bolometer optically coupled to a composite infrared bolometer [J].
Bobin, C ;
Bekes, I ;
Hadjout, JP ;
Coron, N ;
Leblanc, J ;
deMarcillac, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (2-3) :453-457
[5]  
BUCCI C, 2001, MPIPHE200102
[6]   LOW-ENERGY X-RAY-DETECTION IN CRYOGENIC DETECTORS WITH TUNGSTEN THERMOMETERS [J].
COLLING, P ;
NUCCIOTTI, A ;
BUCCI, C ;
COOPER, S ;
FERGER, P ;
FRANK, M ;
NAGEL, U ;
PROBST, F ;
SEIDEL, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 354 (2-3) :408-416
[7]  
FRANK T, 2001, 7 INT C ADV TECHN PA
[8]  
FRANK T, 2002, THESIS TU MUNCHEN M
[9]   Quasiparticle diffusion over several mm in cryogenic detectors [J].
Loidl, M ;
Cooper, S ;
Meier, O ;
Pröbst, F ;
Sáfran, G ;
Seidel, W ;
Sisti, M ;
Stodolsky, L ;
Uchaikin, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (2-3) :440-446
[10]   CALORIMETRIC IONIZATION DETECTOR [J].
LUKE, PN ;
BEEMAN, J ;
GOULDING, FS ;
LABOV, SE ;
SILVER, EH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (03) :406-409