Detection of multiple toxic agents using a planar array immunosensor

被引:104
作者
Wadkins, RM [1 ]
Golden, JP [1 ]
Pritsiolas, LM [1 ]
Ligler, FS [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
biosensor; multianalyte; immunoassay; CCD; fluorescence; array;
D O I
10.1016/S0956-5663(97)00113-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A planar array immunosensor, equipped with a charge-coupled device (CCD) as a detector, was used to simultaneously detect 3 toxic analytes. Wells approximately 2 mm in diameter were formed on glass slides using a photoactivated optical adhesive. Antibodies against staphylococcal enterotoxin B (SEB), ricin, and Yersinia pestis were covalently attached to the bottoms of the circular wells to form the sensing surface. Rectangular wells containing chicken immunoglobulin were used as alignment markers and to generate control signals. After removing the optical adhesive, the slides were mounted over a scientific grade CCD operating at ambient temperature in inverted (multipin phasing) mode. A two-dimensional graded index of refraction lens at-ray was used to focus the sensing surface onto the CCD. Solutions of toxins were then placed on the slide. After rinsing, Cy5-labeled antibodies were introduced. The identity and amount of toxin bound at each location on the slide were determined by quantitative image analysis. Concentrations as low as 25 ng/mL of ricin, 15 ng/mL of pestis F1 antigen, and 5 ng/mL of SEB could be routinely measured. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:407 / 415
页数:9
相关论文
共 24 条
  • [1] [Anonymous], 1991, FIBER OPTIC CHEM SEN
  • [2] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [3] MICROPATTERNING PROTEINS AND SYNTHETIC PEPTIDES ON SOLID SUPPORTS - A NOVEL APPLICATION FOR MICROELECTRONICS FABRICATION TECHNOLOGY
    BRITLAND, S
    PEREZARNAUD, E
    CLARK, P
    MCGINN, B
    CONNOLLY, P
    MOORES, G
    [J]. BIOTECHNOLOGY PROGRESS, 1992, 8 (02) : 155 - 160
  • [4] FABRICATION OF PATTERNED SENSOR ARRAYS WITH ARYL AZIDES ON A POLYMER-COATED IMAGING OPTICAL-FIBER BUNDLE
    BRONK, KS
    WALT, DR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (20) : 3519 - 3520
  • [5] DYNAMIC SUPPRESSION OF INTERFACE-STATE DARK CURRENT IN BURIED-CHANNEL CCDS
    BURKE, BE
    GAJAR, SA
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1991, 38 (02) : 285 - 290
  • [6] DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR
    CAO, LK
    ANDERSON, GP
    LIGLER, FS
    EZZELL, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) : 336 - 341
  • [7] CASS AEG, 1990, BIOSENSORS
  • [8] BIOSENSOR DEVELOPMENT AT THE UNIVERSITY-OF-UTAH
    CHRISTENSEN, D
    JOHANSSON, T
    PETELENZ, D
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1994, 13 (03): : 388 - 395
  • [9] EGGERS M, 1994, BIOTECHNIQUES, V17, P516
  • [10] LIGHT-DIRECTED, SPATIALLY ADDRESSABLE PARALLEL CHEMICAL SYNTHESIS
    FODOR, SPA
    READ, JL
    PIRRUNG, MC
    STRYER, L
    LU, AT
    SOLAS, D
    [J]. SCIENCE, 1991, 251 (4995) : 767 - 773