In situ DMSO hydration measurements of HTS compound libraries

被引:35
作者
Ellson, R [1 ]
Stearns, R [1 ]
Mutz, M [1 ]
Brown, C [1 ]
Browning, B [1 ]
Harris, D [1 ]
Qureshi, S [1 ]
Shieh, J [1 ]
Wold, D [1 ]
机构
[1] Labcyte Inc, Sunnyvale, CA 94089 USA
关键词
DMSO hydration; acoustic hydration measurement; quality control; microtiter plates;
D O I
10.2174/1386207054867382
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Compounds used in high throughput screening (HTS) are typically dissolved in DMSO. These solutions are stored automation-friendly racks of wells or tubes. DMSO is hygroscopic and quickly absorbs water from the atmosphere. When present in DMSO compound solutions, water can accelerate degradation and precipitation. Understanding DMSO hydration in an HTS compound library can improve storage and screening methods by managing the impact of water on compound stability. A non-destructive, acoustic method compatible with HTS has been developed to measure water content in DMSO solutions. Performance of this acoustic method was compared with an optical technique and found to be in good agreement. The accuracy and precision of acoustic measurements was shown to be under 3% over the tested range of DMSO solutions (0% to 35% water by volume) and insensitive to the presence of HTS compounds at typical storage concentrations. Time course studies of hydration for wells in 384-well and 1536-well microplates were performed. Well geometry, fluid volume, well position and atmospheric conditions were all factors in hydration rate. High rates of hydration were seen in lower-volume fills, higher-density multi-well plates and when there was a large differential between the humidity of the lab and the water content of the DMSO. For example, a 1536-well microplate filled with 2 mu L of 100% DMSO exposed for one hour to a laboratory environment with similar to 40% relative humidity will absorb over 6% water by volume. Understanding DMSO hydration rates as well as the ability to reverse library hydration are important steps towards managing stability and availability of compound libraries.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 18 条
[1]  
BECKNER C, 2002, DDT
[2]  
Chen M, 2003, PERFORM RES, V8, P3
[3]  
FILLERS WS, 2004, DRUG DISCOVERY WORLD, V5, P86
[4]   A new method for the analytical determination water in liquids and solids. [J].
Fischer, K .
ANGEWANDTE CHEMIE, 1935, 48 :0394-0396
[5]  
*GAYL CHEM, 1998, B GAYL CHEM, V101
[6]  
HEATON Z, 2002, DDT
[7]   THERMAL EMISSION DECAY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
IMHOF, RE ;
MCKENDRICK, AD ;
XIAO, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11) :5203-5213
[8]  
KRAUTKRAMER J, 1977, ULTRASONIC TESTING M
[9]  
LIPINSKI CA, 2004, LABFUSION
[10]  
LIPISNKI CA, 2004, IQPC COMPOUND MANAGE