Purity assessment and resolution of tetracycline hydrochloride samples analysed using high-performance liquid chromatography with diode array detection

被引:53
作者
De Braekeleer, K
de Juan, A
Massart, DL
机构
[1] Free Univ Brussels, ChemoAC, B-1090 Brussels, Belgium
[2] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
purity assessment; orthogonal projection approach; fixed size moving window evolving factor analysis approach; multivariate curve resolution alternating least-squares approach; tetracyclines;
D O I
10.1016/S0021-9673(98)00985-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-performance liquid chromatography with diode array detection (HPLC-DAD) was used for the analysis of a tetracycline hydrochloride sample (TC-HCl). The analytical search for impurities in TC-HCl is complicated, because the standards are not always available and because unexpected impurities are produced by new mutants during fermentation. Due to this it is useful to check the purity of the peaks in the chromatogram even when it is obtained with an optimised analytical technique. The homogeneity of the individual peaks in the HPLC-DAD chromatogram was checked using chemometric methods such as the orthogonal projection approach (OPA) and the fixed size moving window evolving factor analysis approach (FSW-EFA). After the selection of the number of components, the experimental data were resolved in the pure component spectra and the individual concentration profiles. The multivariate curve resolution alternating least-squares approach (MCR-ALS) was applied for this purpose on the single HPLC-DAD chromatograms (two-way data) and on sets of such chromatograms (three-way data). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 86
页数:20
相关论文
共 30 条
[1]   Migration behavior and separation of tetracycline antibiotics by micellar electrokinetic chromatography [J].
Chen, YC ;
Lin, CE .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (01) :95-105
[2]   Evaluation of the orthogonal projection approach (OPA) and the SIMPLISMA approach on the Windig standard spectral data sets [J].
De Braekeleer, K ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 39 (02) :127-141
[3]   EXPERIMENTAL-DESIGN ON LIQUID-CHROMATOGRAPHIC PARAMETERS IN THE ANALYSIS OF TETRACYCLINE ON POLY(STYRENE DIVINYLBENZENE) [J].
DEBEER, JO ;
HOOGMARTENS, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1239-1250
[4]   CALCULATION OF EQUILIBRIUM-CONSTANTS FROM MULTIWAVELENGTH SPECTROSCOPIC DATA .3. MODEL-FREE ANALYSIS OF SPECTROPHOTOMETRIC AND ELECTRON-SPIN-RESONANCE TITRATIONS [J].
GAMPP, H ;
MAEDER, M ;
MEYER, CJ ;
ZUBERBUHLER, AD .
TALANTA, 1985, 32 (12) :1133-1139
[5]   Validation of alternating least-squares multivariate curve resolution for chromatographic resolution and quantitation [J].
Gargallo, R ;
Tauler, R ;
CuestaSanchez, F ;
Massart, DL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :279-286
[6]  
HUBER L, 1989, APPL DIODE ARRAY DET, P73
[7]   EVOLVING FACTOR-ANALYSIS IN THE PRESENCE OF HETEROSCEDASTIC NOISE [J].
KELLER, HR ;
MASSART, DL ;
LIANG, YZ ;
KVALHEIM, OM .
ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) :29-36
[8]   PEAK PURITY CONTROL IN LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION BY A FIXED SIZE MOVING WINDOW EVOLVING FACTOR-ANALYSIS [J].
KELLER, HR ;
MASSART, DL .
ANALYTICA CHIMICA ACTA, 1991, 246 (02) :379-390
[9]   EFFECT OF THE SCAN TIME ON METHODS BASED ON EVOLVING FACTOR-ANALYSIS IN LIQUID-CHROMATOGRAPHY [J].
KELLER, HR ;
MASSART, DL ;
KIECHLE, P ;
ERNI, F .
ANALYTICA CHIMICA ACTA, 1992, 256 (01) :125-131
[10]   EVOLVING FACTOR-ANALYSIS [J].
KELLER, HR ;
MASSART, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1992, 12 (03) :209-224