Determination of functional rotation axes during elevation of the shoulder complex

被引:20
作者
Doorenbosch, CAM
Mourits, AJJM
Veeger, DHEJ
机构
[1] Free Univ Amsterdam Hosp, Dept Rehabil Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Fac Human Movement Sci, Amsterdam, Netherlands
[3] Delft Univ Technol, Dept Mech Engn, Man Machine Syst Grp, Delft, Netherlands
关键词
biomechanics; isokinetics; movement analysis; upper extremity;
D O I
10.2519/jospt.2001.31.3.133
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: A cross-sectional, descriptive study of shoulder movements conducted on nonimpaired subjects. Objective: To investigate whether a single functional rotation axis about the shoulder complex can be determined during elevation in the coronal or sagittal planes, and to identify their location. Background: Accurate measurement of isokinetic torques about a joint requires alignment of the dynamometer axis with an assumed rotation axis of the joint. To assess shoulder function on a dynamometer, the location of a single rotation axis is not evident because the shoulder joint motion is based on several anatomical joints. Therefore, the rotation axis where humerothoracic movements occur should be judged as a functional rotation axis. Methods and Measures: During slow elevation movements in the sagittal and coronal plane, the position of the epicondyle and acromion were recorded with a motion analysis system. The motion trajectory of the elbow coordinates was fitted to a circle and considered an estimate of the functional shoulder joint rotation axis in the specified plane. Results: The fitted trajectory appeared to be very accurate (root-mean-square error < 2%; N = 7). In the sagittal plane, the estimated functional rotation axis was found at the humeral head; in the coronal plane, it was located about 13 centimeters medial relative to the acromion. Conclusion: The shoulder complex of nonimpaired subjects can act as a hinge joint of the upper arm relative to the thorax during elevation in each measured plane.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 22 条
[1]  
BEASLEY W C, 1956, Phys Ther Rev, V36, P21
[2]   Velocity effects on the scapulo-humeral rhythm [J].
de Groot, JH ;
Valstar, ER ;
Anvert, HJ .
CLINICAL BIOMECHANICS, 1998, 13 (08) :593-602
[3]   Effect of different arm loads on the position of the scapula in abduction postures [J].
de Groot, JH ;
van Woensel, W ;
van der Helm, FCT .
CLINICAL BIOMECHANICS, 1999, 14 (05) :309-314
[4]  
DENNIS JE, 1983, NUMERICAL METHODS UN
[5]   CLINICAL APPLICABILITY OF ISOKINETICS - A REVIEW [J].
DVIR, Z .
CLINICAL BIOMECHANICS, 1991, 6 (03) :133-144
[6]  
Inman VT, 1944, J BONE JOINT SURG, V26, P1
[7]   The influence of subject and test design on dynamometric measurements of extremity muscles [J].
Keating, JL ;
Matyas, TA .
PHYSICAL THERAPY, 1996, 76 (08) :866-889
[8]   Validation of a functional method for the estimation of hip joint centre location [J].
Leardini, A ;
Cappozzo, A ;
Catani, F ;
Toksvig-Larsen, S ;
Petitto, A ;
Sforza, V ;
Cassanelli, G ;
Giannini, S .
JOURNAL OF BIOMECHANICS, 1999, 32 (01) :99-103
[9]  
Levenberg K., 1944, Quarterly of Applied Mathematics, V2, P164, DOI [10.1090/QAM/10666, 10.1090/qam/10666, DOI 10.1090/QAM/10666]
[10]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441