A "Mix and read" assay for insulin using fluorometric microvolume assay technology

被引:4
作者
Toney, JH
Ogawa, A
Blair, M
Park, YW
机构
[1] Merck Res Labs, Dept Microbial Biochem, Rahway, NJ 07065 USA
[2] Merck Res Labs, Metab Disorders Diabet, Rahway, NJ 07065 USA
关键词
D O I
10.1089/154065803322302772
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a novel, "mix and read" immunoassay for insulin in biological samples using FMAT. Current commercial assays for insulin require multiple washing steps and can be expensive. The insulin assay described is a simple two-step, time-saving assay and amenable to robotics. The linear response for the fluorometric signal is comparable to that observed using classical ELISA and RIA. A series of mouse plasma samples were tested for insulin levels and yielded results comparable to that measured using a commercial ELISA for insulin.
引用
收藏
页码:521 / 525
页数:5
相关论文
共 11 条
[1]  
Chevenne D, 1999, DIABETES METAB, V25, P459
[2]   Assays for insulin, proinsulin(s) and C-peptide [J].
Clark, PM .
ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 :541-564
[3]   Measurement of interferon-γ by high-throughput fluorometric microvolume assay technology system [J].
Komatsu, N ;
Shichijo, S ;
Maeda, Y ;
Itoh, K .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 263 (1-2) :169-176
[4]   Polymer mineralization in soils: Effects of cold storage on microbial populations and biodegradation potential [J].
Lee, JS ;
Daniels, BL ;
Eberiel, DT ;
Farrell, RE .
JOURNAL OF POLYMERS AND THE ENVIRONMENT, 2000, 8 (02) :81-89
[5]   Homogeneous liposome immunoassay for insulin using phospholipase C from Clostridium perfringens [J].
Lim, SJ ;
Kim, CK .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (01) :89-95
[6]  
Lovendahl P, 2002, J ANIM SCI, V80, P191
[7]   A generic particle-based nonradioactive homogeneous multiplex method for high-throughput screening using microvolume fluorimetry [J].
Martens, C ;
Bakker, A ;
Rodriguez, A ;
Mortensen, RB ;
Barrett, RW .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (01) :20-31
[8]   Homogeneous cell- and bead-based assays for high throughput screening using fluorometric microvolume assay technology [J].
Miraglia, S ;
Swartzman, EE ;
Mellentin-Michelotti, J ;
Evangelista, L ;
Smith, C ;
Gunawan, I ;
Lohman, K ;
Goldberg, EM ;
Manian, B ;
Yuan, PM .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (04) :193-204
[9]   A homogeneous and multiplexed immunoassay for high-throughput screening using fluorometric microvolume assay technology [J].
Swartzman, EE ;
Miraglia, SJ ;
Mellentin-Michelotti, J ;
Evangelista, L ;
Yuan, PM .
ANALYTICAL BIOCHEMISTRY, 1999, 271 (02) :143-151
[10]   A simple statistical parameter for use in evaluation and validation of high throughput screening assays [J].
Zhang, JH ;
Chung, TDY ;
Oldenburg, KR .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (02) :67-73