Dirty water from dairy farms, I: biochemical characteristics

被引:43
作者
Cumby, TR
Brewer, AJ
Dimmock, SJ
机构
[1] Silsoe Res Inst, Bedford MK45 4HS, England
[2] Farming & Rural Conservat Agcy, London SW1P 3JR, England
关键词
cows; daily; dirty water; effluents; aerobic treatment; irrigation; storage;
D O I
10.1016/S0960-8524(98)00104-7
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The quality of dirty water arising on 20 dairy farms in England and Wales was investigated. Farms were selected where existing pumped dirty irrigation systems allowed for appropriate sampling. Each farm was visited on three occasions during the year, in March, June and September, to sample dirty water. Considerable variations were found in total solids (TS) with concentrations ranging from 0.08% to 4.64%. Marked seasonal variations were observed with the highest concentrations in June and the lowest in March. The biochemical characteristics of dirty water showed fairly good correlations between the following parameters and TS: 5-day Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Kjeldahl nitrogen, potassium and phosphate. No corresponding correlation was found for ammoniacal nitrogen concentrations. These findings indicated that effective biological treatment for dirty water was feasible. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 3 条
  • [1] [Anonymous], STAND METH EX WAT WA
  • [2] BREWER AJ, 1992, CO13001 ADAS MILK MA
  • [3] *ENV AG, 1996, WAT POLL INC ENGL WA