Evaluation of pulsed dose oxygen delivery during exercise in patients with severe chronic obstructive pulmonary disease

被引:27
作者
Garrod, R [1 ]
Bestall, JC [1 ]
Paul, E [1 ]
Wedzicha, JA [1 ]
机构
[1] London Chest Hosp, St Bartholomews & Royal London Sch Med & Dent, Acad Dept Resp Med, London E2 9JX, England
关键词
chronic obstructive pulmonary disease; exercise; oxygen therapy; pulsed dose oxygen delivery;
D O I
10.1136/thx.54.3.242
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-Oxygen conserving devices may lead to substantial increases in the duration of oxygen provided. A study was undertaken to compare the performance of a pulsed dose oxygen delivery (PDOD) system with continuous flow oxygen or air during a maximal walking test. Methods-Fourteen patients with chronic obstructive pulmonary disease (COPD) and arterial oxygen desaturation on exercise (mean (SD) forced expiratory volume in one second (FEV,) 0.83 (0.28) 1, arterial oxygen pressure (Pao,) 8.38 (1.24) kPa, arterial carbon dioxide pressure (Paco(2)) 5.95 (0.86) kPa) were randomised to perform a walking test using air administered via a cylinder or continuous flow oxygen at 2 l/min or by a PDOD system. Results-There was no significant difference in the mean arterial oxygen saturation (Sao(2)) using the PDOD system or with continuous flow oxygen (p = 0.33). Patients showed greatest desaturation whilst walking with the air cylinder (Sao(2) 79.2 (8.59)%) which was significantly different from the desaturation with both continuous flow oxygen (87.6 (5.85)%, p 0.001) and PDOD (85.6 (7.36)%, p 0.004). There was no significant difference between the distance walked using oxygen delivered at 2 l/min by continuous flow or via the PDOD (p = 0.72; CI 0.33 to 1.08). The mean (SD) distance walked on continuous flow oxygen (203.6 (106.1) m) and PDOD (207.9 (109.8) m) was significantly greater than the distance walked with the air cylinder (188.6 (110.02) m); (1.12 fold increase in distance, CI 1.01 to 1.23, p 0.02, and 1.14 fold increase in distance, CI 1.01 to 1.28, p = 0.03, respectively). Conclusions-These findings suggest that the pulsed dose oxygen conserving device was as effective as continuous flow oxygen in maintaining arterial oxygen saturation and that the use of this device was associated with similar improvements in exercise tolerance to patients taking continuous flow oxygen therapy.
引用
收藏
页码:242 / 244
页数:3
相关论文
共 11 条
[1]   PERFORMANCE OF A DEMAND OXYGEN SAVER SYSTEM DURING REST, EXERCISE, AND SLEEP IN HYPOXEMIC PATIENTS [J].
BOWER, JS ;
BROOK, CJ ;
ZIMMER, K ;
DAVIS, D .
CHEST, 1988, 94 (01) :77-80
[2]  
BRADLEY BL, 1978, AM REV RESPIR DIS, V118, P239
[3]   COMPARISON OF 6 OXYGEN DELIVERY SYSTEMS FOR COPD PATIENTS AT REST AND DURING EXERCISE [J].
BRAUN, SR ;
SPRATT, G ;
SCOTT, GC ;
ELLERSIECK, M .
CHEST, 1992, 102 (03) :694-698
[4]  
BURDON JGW, 1982, AM REV RESPIR DIS, V126, P825
[5]   SUPPLEMENTAL OXYGEN AND EXERCISE ABILITY IN CHRONIC OBSTRUCTIVE AIRWAYS DISEASE [J].
DAVIDSON, AC ;
LEACH, R ;
GEORGE, RJD ;
GEDDES, DM .
THORAX, 1988, 43 (12) :965-971
[6]   PORTABLE OXYGEN-THERAPY - ASSESSMENT AND USAGE [J].
LOCK, SH ;
PAUL, EA ;
RUDD, RM ;
WEDZICHA, JA .
RESPIRATORY MEDICINE, 1991, 85 (05) :407-412
[7]   ARTERIALIZED EARLOBE BLOOD-GAS ANALYSIS - AN UNDERUSED TECHNIQUE [J].
PITKIN, AD ;
ROBERTS, CM ;
WEDZICHA, JA .
THORAX, 1994, 49 (04) :364-366
[8]   Comparison of the efficacy of a demand oxygen delivery system with continuous low flow oxygen in subjects with stable COPD and severe oxygen desaturation on walking [J].
Roberts, CM ;
Bell, J ;
Wedzicha, JA .
THORAX, 1996, 51 (08) :831-834
[9]   DEVELOPMENT OF A SHUTTLE WALKING TEST OF DISABILITY IN PATIENTS WITH CHRONIC AIRWAYS OBSTRUCTION [J].
SINGH, SJ ;
MORGAN, MDL ;
SCOTT, S ;
WALTERS, D ;
HARDMAN, AE .
THORAX, 1992, 47 (12) :1019-1024
[10]   DEMAND OXYGEN DELIVERY DURING EXERCISE [J].
TIEP, BL ;
CARTER, R ;
NICOTRA, B ;
BERRY, J ;
PHILLIPS, RE ;
OTSAP, B .
CHEST, 1987, 91 (01) :15-20