Factors affecting the analytical applications of zeolite modified electrodes: indirect detection of nonelectroactive cations

被引:46
作者
Walcarius, A [1 ]
机构
[1] Univ H Poincare Nancy 1, UMR 7564 CNRS, Lab Chim Phys Environm, F-54600 Villers Les Nancy, France
关键词
zeolite modified electrodes; carbon paste; ion exchange; indirect detection; zeolites; copper; flow injection analysis;
D O I
10.1016/S0003-2670(99)00095-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon paste electrodes modified with several types of copper-doped zeolites were evaluated as sensors for nonelectroactive cations in a Bow injection system. After having described the amperometric detection mechanism and proposed an efficient procedure to achieve good reproducibility in successive measurements, it was shown how various experimental parameters influenced the quantitative determination of potassium ions (chosen as reference cationic species), such as the applied potential, mobile phase composition and flow rate, the ionic strength of the sample solution, or the injection volume. The analysis was then extended to other mono- and divalent cations and selectivity series were established in relation to wherever zeolites A, X, Y, or clinoptilolite was used. It was concluded that the sensor's response was mainly governed by the diffusion of both the electron transfer co-factor (Cu2+ species) and the cationic analytes, rather than by the thermodynamic predictions related to ion exchange equilibrium despite the fact that the amperometric detection was allowed to occur only after the exchange of Cu2+ species for the cationic analyte. Detection limits around 10(-6) M were obtained for the analysis of alkali metal, ammonium, calcium and magnesium ions using the copper-doped zeolite Y modified electrode in a 0.01 M tetrabutylammonium bromide mobile phase. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 47 条
[1]   EFFECTS OF SUPPORTING ELECTROLYTE AND ZEOLITE CO-CATIONS ON THE ELECTROCHEMICAL RESPONSE OF ZEOLITE-MODIFIED ELECTRODES [J].
BAKER, MD ;
SENARATNE, C ;
ZHANG, J .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (21) :3187-3192
[2]   TRACE ANALYSIS IN SOLUTION USING ZEOLITE-MODIFIED ELECTRODES [J].
BAKER, MD ;
SENARATNE, C .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :697-700
[3]   SILVER ZEOLITE-MODIFIED ELECTRODES - ELECTRON-TRANSPORT MECHANISM AND ION-EXCHANGE KINETICS FOR PARTIALITY SILVER EXCHANGED ZEOLITE-Y [J].
BAKER, MD ;
ZHANG, JW ;
MCBRIEN, M .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (17) :6635-6639
[4]   SILVER ZEOLITE-MODIFIED ELECTRODES - IMPORTANCE OF ION-EXCHANGE AND CATION SITE EFFECTS [J].
BAKER, MD ;
SENARATNE, C ;
ZHANG, JW .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (06) :1668-1673
[5]  
BAKER MD, 1994, ELECTROCHEMISTRY NOV
[6]  
BARD AJ, 1992, MOL DESIGN ELECTRODE
[7]   ZEOLITE-ENCAPSULATED AND CLAY-INTERCALATED METAL PORPHYRIN, PHTHALOCYANINE AND SCHIFF-BASE COMPLEXES AS MODELS FOR BIOMIMETIC OXIDATION CATALYSTS - AN OVERVIEW [J].
BEDIOUI, F .
COORDINATION CHEMISTRY REVIEWS, 1995, 144 :39-68
[8]  
BRECK DW, 1984, ZEOLITES MOL SIEVES
[9]  
Briot E., 1997, Curr. Top. Electrochem., V4, P87
[10]   Determination of copper by zeolite molecular sieve modified electrode [J].
Chen, B ;
Goh, NK ;
Chia, LS .
ELECTROCHIMICA ACTA, 1997, 42 (04) :595-604