Clinical evaluation of irreversible data compression for computed radiography of the chest

被引:11
作者
Egashira, K [1 ]
Nakata, H [1 ]
Watanabe, H [1 ]
Uchida, K [1 ]
Nakamura, K [1 ]
Ishino, Y [1 ]
Horino, K [1 ]
Yoshikawa, R [1 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Radiol, Yahatanishi Ku, Kitakyushu, Fukuoka 807, Japan
关键词
computed radiography; data compression; chest;
D O I
10.1007/BF03178080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal cases, with an additional 15 cases of lung cancers with solitary lung nodules, were selected from the file. A pair of hard copies of original images and images reconstructed using type III compression was made for each case. Six radiologists evaluated the image quality by visual rating and receiver operating characteristic (ROC) curve analysis. For all five anatomic regions of normal cases, "original equal to compressed" was the most common response, followed by "original significantly better than compressed." When abnormal cases were evaluated for diagnostic information, there was no significant difference between the compressed and original images. ROC curve analysis on lung nodules with lung cancer showed no significant difference between the two. Compressed CR images using the type III irreversible technique are clinically applicable and acceptable despite slight degradation of image quality. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:176 / 181
页数:6
相关论文
共 15 条
[1]   APPLICATION OF WAVELET COMPRESSION TO DIGITIZED RADIOGRAPHS [J].
GOLDBERG, MA ;
PIVOVAROV, M ;
MAYOSMITH, WW ;
BHALLA, MP ;
BLICKMAN, JG ;
BRAMSON, RT ;
BOLAND, GWL ;
LLEWELLYN, HJ ;
HALPERN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :463-468
[2]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[3]   CLINICAL-EVALUATION OF IRREVERSIBLE IMAGE COMPRESSION - ANALYSIS OF CHEST IMAGING WITH COMPUTED RADIOGRAPHY [J].
ISHIGAKI, T ;
SAKUMA, S ;
IKEDA, M ;
ITOH, Y ;
SUZUKI, M ;
IWAI, S .
RADIOLOGY, 1990, 175 (03) :739-743
[4]   Subtle pulmonary disease: Detection with computed radiography versus conventional chest radiography [J].
Ishigaki, T ;
Endo, T ;
Ikeda, M ;
Kono, M ;
Yoshida, S ;
Ikezoe, J ;
Murata, K ;
Matsumoto, M .
RADIOLOGY, 1996, 201 (01) :51-60
[5]   Detection of subtle interstitial abnormalities of the lungs on digitized chest radiographs: Acceptable data compression ratios [J].
Kido, S ;
Ikezoe, J ;
Kondoh, H ;
Takeuchi, N ;
Johkoh, T ;
Kohno, N ;
Tomiyama, N ;
Naito, H ;
Arisawa, J ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :111-115
[6]   TECHNICAL ADVANCES IN CHEST RADIOGRAPHY [J].
MACMAHON, H ;
VYBORNY, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1049-1059
[7]   DATA-COMPRESSION - EFFECT ON DIAGNOSTIC-ACCURACY IN DIGITAL CHEST RADIOGRAPHY [J].
MACMAHON, H ;
DOI, K ;
SANADA, S ;
MONTNER, SM ;
GIGER, ML ;
METZ, CE ;
NAKAMORI, N ;
YIN, FF ;
XU, XW ;
YONEKAWA, H ;
TAKEUCHI, H .
RADIOLOGY, 1991, 178 (01) :175-179
[8]  
METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
[9]  
Mori T, 1994, J Thorac Imaging, V9, P23, DOI 10.1097/00005382-199420000-00004
[10]   PORTABLE CHEST IMAGING - COMPARISON OF STORAGE PHOSPHOR DIGITAL, ASYMMETRIC SCREEN-FILM, AND CONVENTIONAL SCREEN-FILM SYSTEMS [J].
NIKLASON, LT ;
CHAN, HP ;
CASCADE, PN ;
CHANG, CL ;
CHEE, PW ;
MATHEWS, JF .
RADIOLOGY, 1993, 186 (02) :387-393