Robotic coronary artery bypass grafting (CABG) - the Leipzig experience

被引:21
作者
Falk, V [1 ]
Jacobs, S [1 ]
Gummert, J [1 ]
Walther, T [1 ]
机构
[1] Univ Leipzig, Ctr Heart, Dept Cardiac Surg, D-04289 Leipzig, Germany
关键词
D O I
10.1016/S0039-6109(03)00165-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Technical and anatomical limitations as well as human factors complicate endoscopic coronary bypass surgery. Computer-enhanced telemanipulation systems overcome some of these shortcomings by restoring the dexterity and precision of a distant operator (surgeon) within a confined space. Endoscopic coronary artery bypass grafting (CABG) has evolved from a merely experimental approach to a clinical concept. Although CABG was initially exclusively performed on the arrested heart, adjunct technologies such as endoscopic vacuum-assisted stabilizers now allow a closed-chest, beating-heart procedure. The development of anastomotic devices, and further refinements in telemanipulator technology, optical systems, and image-guided augmented-reality scenarios will greatly facilitate endoscopic bypass grafting in the future.
引用
收藏
页码:1381 / +
页数:7
相关论文
共 20 条
[1]   Pain is significantly reduced by cryoablation therapy in patients with lateral minithoracotomy [J].
Bucerius, J ;
Metz, S ;
Walther, T ;
Doll, N ;
Falk, V ;
Diegeler, A ;
Autschbach, R ;
Mohr, FW .
ANNALS OF THORACIC SURGERY, 2000, 70 (03) :1100-1104
[2]   The revival of surgical treatment for isolated proximal high grade LAD lesions by minimally invasive coronary artery bypass grafting [J].
Diegeler, A ;
Spyrantis, N ;
Matin, M ;
Falk, V ;
Hambrecht, R ;
Autschbach, R ;
Mohr, FW ;
Schuler, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (05) :501-504
[3]  
Falk V, 1996, J HEART VALVE DIS, V5, P630
[4]   Total endoscopic computer enhanced coronary artery bypass grafting [J].
Falk, V ;
Diegeler, A ;
Walther, T ;
Banusch, J ;
Brucerius, J ;
Raumans, J ;
Autschbach, R ;
Mohr, FW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) :38-45
[5]   Transabdominal endoscopic computer-enhanced coronary artery bypass grafting [J].
Falk, V ;
Moll, FH ;
Rosa, DJ ;
Daunt, D ;
Diegeler, A ;
Walther, T ;
Mohr, FW .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1555-1557
[6]   Quality of computer enhanced totally endoscopic coronary bypass graft anastomosis - comparison to conventional technique [J].
Falk, V ;
Gummert, JF ;
Walther, T ;
Hayase, M ;
Berry, GJ ;
Mohr, FW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (03) :260-264
[7]   Dexterity enhancement in endoscopic surgery by a computer-controlled mechanical wrist [J].
Falk, V ;
McLoughlin, J ;
Guthart, G ;
Salisbury, JK ;
Walther, T ;
Gummert, J ;
Mohr, FW .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1999, 8 (04) :235-242
[8]  
Falk V, 1999, Heart Surg Forum, V2, P199
[9]  
Falk V, 2000, HEART SURG FORUM, V3, P29
[10]   Robot-assisted minimally invasive solo mitral valve operation [J].
Falk, V ;
Walther, T ;
Autschbach, R ;
Diegeler, A ;
Battellini, R ;
Mohr, FW .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (02) :470-471