Stereotactic core biopsy reduces the reexcision rate and the cost of mammographically detected cancer

被引:48
作者
Lind, DS [1 ]
Minter, R
Steinbach, B
Abbitt, P
Lanier, L
Haigh, L
Vauthey, JN
Russin, M
Hackett, R
Copeland, EM
机构
[1] Univ Florida, Coll Med, Dept Surg, Gainesville, FL 32610 USA
[2] Univ Florida, Coll Med, Dept Radiol, Gainesville, FL 32610 USA
[3] Univ Florida, Coll Med, Dept Pathol, Gainesville, FL 32610 USA
[4] Univ Florida, Coll Med, Dept Clin Resource Management, Gainesville, FL 32610 USA
关键词
stereotactic biopsy; cost; reexcision; breast cancer;
D O I
10.1006/jsre.1998.5380
中图分类号
R61 [外科手术学];
学科分类号
摘要
The management of patients with mammographic abnormalities is rapidly shifting from needle-localized surgical biopsy (NLB) to stereotactic core biopsy (SCB). The precise role of SCE in the management of nonpalpable breast cancer remains to be defined. The purpose of this study was to compare SCB to NLB in the diagnosis of mammographically detected breast cancer in women who underwent breast-conserving surgery, The records of all patients with nonpalpable breast cancer who underwent breast-conserving surgery from 1/1/95 to 6/1/97 were analyzed with respect to method of diagnosis, time interval from detection to diagnosis and breast-conserving surgery, volume of breast tissue excised, margin status and reexcision rate, number of surgical procedures, and total charges and costs per patient. During a 30-month period, 117 patients with nonpalpable breast cancer underwent breast-conserving surgery. The diagnosis was made by NLB in 69 patients and SCB in 48 patients. The time from detection to diagnosis and breast-conserving surgery was 1.7 +/- 0.5 and 8.1 +/- 1.2 days for SCE patients and 6.8 +/- 1.3 and 16.9 +/- 2.3 days for NLB patients (P < 0.01). The volume of breast tissue removed was 117.9 +/- 5.6 cm(3) for SCB patients versus 75.2 +/- 2.9 cm(3) for NLB patients (P < 0.01). Three SCB patients (6%) had positive margins, while 38 NLB patients (55%) had positive margins (P < 0.01). Only 1 SCB patient (2%) was reexcised, while 34 NLB patients (50%) were reexcised (P < 0.01). Eighty-nine percent of SCB patients had a single surgical procedure compared to 39% of NLB patients (P < 0.001). Patients who underwent SCB had reduced total charges and total costs per patient compared to NLB patients ($11,700 +/- $554 and $3537 +/- $167 per SCB patient versus $15,654 +/- $706 and $4853 +/- $198 per NLB patient, P < 0.0001). Stereotactic core biopsy shortens the time from detection at mammography to diagnosis and breast-conserving therapy, permits appropriate discussion of treatment alternatives, reduces the positive margin rate and reexcision rate, and may represent a significant cost savings in the management of nonpalpable breast cancer. (C) 1998 Academic Press.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 16 条
  • [1] SURGICAL MARGINS AFTER NEEDLE-LOCALIZATION BREAST BIOPSY
    ACOSTA, JA
    GREENLEE, JA
    GUBLER, KD
    GOEPFERT, CJ
    RAGLAND, JJ
    [J]. AMERICAN JOURNAL OF SURGERY, 1995, 170 (06) : 643 - 646
  • [2] Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists
    Bassett, L
    Winchester, DP
    Caplan, RB
    Dershaw, DD
    Dowlatshahi, K
    Evans, WP
    Fajardo, LL
    Fitzgibbons, PL
    Henson, DE
    Hutter, RVP
    Morrow, M
    Paquelet, JR
    Singletary, SE
    Curry, J
    WilcoxBuchalla, P
    Zinninger, M
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) : 171 - +
  • [3] BORGEN PI, 1995, CURR PROB SURG, V3, P193
  • [4] Brenner RJ, 1997, ACAD RADIOL, V4, P419
  • [5] Burns RP, 1997, AM J SURG, V173, P9, DOI 10.1016/S0002-9610(96)00374-1
  • [6] ANALYSIS OF RESIDUAL CANCER AFTER DIAGNOSTIC BREAST BIOPSY - AN ARGUMENT FOR FINE-NEEDLE ASPIRATION CYTOLOGY
    COX, CE
    REINTGEN, DS
    NICOSIA, SV
    KU, NN
    BAEKEY, P
    CAREY, LC
    [J]. ANNALS OF SURGICAL ONCOLOGY, 1995, 2 (03) : 201 - 206
  • [7] SELECTIVE USE OF IMAGE-GUIDED LARGE-CORE NEEDLE-BIOPSY OF THE BREAST - ACCURACY AND COST-EFFECTIVENESS
    DOYLE, AJ
    MURRAY, KA
    NELSON, EW
    BRAGG, DG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 281 - 284
  • [8] REPORT OF THE INTERNATIONAL WORKSHOP ON SCREENING FOR BREAST-CANCER
    FLETCHER, SW
    BLACK, W
    HARRIS, R
    RIMER, BK
    SHAPIRO, S
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1993, 85 (20) : 1644 - 1656
  • [9] Gadd MA, 1997, ARCH SURG-CHICAGO, V132, P260
  • [10] Patient perceptions of stereotaxic large-core breast biopsy
    Handy, RB
    Fajardo, LL
    Innis, CA
    Witzke, DB
    Hunter, TB
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (12) : 1007 - 1011