Biomechanical Properties of the Equine Third Metacarpal Bone: In Vivo Quantitative Ultrasonography Versus Ex Vivo Compression and Bending Techniques

被引:5
作者
Fradinho, Maria J. [1 ]
Vale, Ana C. [2 ]
Bernardes, Nuno [3 ]
Caldeira, Rui M. [1 ]
Vaz, Maria Fatima [2 ]
Ferreira-Dias, Graca [1 ]
机构
[1] Univ Lisbon, Fac Med Vet, CIISA, P-1300477 Lisbon, Portugal
[2] Univ Lisbon, IST, Inst Ciencia & Engn Mat & Superficies, Dept Engn Mecan, P-1300477 Lisbon, Portugal
[3] Univ Lisbon, Fac Med Vet, P-1300477 Lisbon, Portugal
关键词
Horse; Third metacarpal bone; Quantitative ultrasonography; Bone mechanical properties; Compression and bending tests; COLLAGEN FIBER ORIENTATION; MECHANICAL-PROPERTIES; CORTICAL BONE; FATIGUE BEHAVIOR; ULTRASOUND; STRAIN; ADAPTATION; SPEED; FRACTURES; MODULUS;
D O I
10.1016/j.jevs.2014.12.016
中图分类号
S85 [动物医学(兽医学)];
学科分类号
090604 [动物药学];
摘要
An experiment was conducted to (1) assess equine cortical bone status in vivo by quantitative ultrasonography (QUS); (2) evaluate certain mechanical properties of the third metacarpal bone (McIII) and to characterize its regional variation along the bone; and (3) compare the in vivo results with the ex vivo mechanical tests on the same bone. Eight adult mares were assessed with a QUS device on the midsection of the right McIII (dorsal and lateral regions). Cortical bone samples from the dorsal and lateral regions of both McIII were collected postmortem and tested in compression and bending. Values of speed of sound (SOS) on the lateral region were higher than for the dorsal one (P < .0001), but they were linearly correlated (r = 0.803; P < .05). In compression, the maximum stress (sigma(max)) was influenced by bone region and bone section, and an interaction was found between these two effects (P < .01). Samples from the dorsal region were stiffer than samples from the lateral region (P < .0001), and lower values of the Young's modulus (E) were obtained on the McIII distal sections (P < .05). Lower bending strength was observed in the distal section of the bone compared with the proximal and the midsection (P < .01). In vivo SOS measurements on the dorsal region were highly correlated with the E obtained from ex vivo compression tests (r(2) = 0.92; P = .0002). These results suggest that QUS could be used as a noninvasive method in the assessment of equine cortical bone mechanical properties. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:198 / 205
页数:8
相关论文
共 36 条
[1]
Quantitative ultrasound methods to assess bone mineral status in children: Technical characteristics, performance, and clinical application [J].
Baroncelli, Giampiero I. .
PEDIATRIC RESEARCH, 2008, 63 (03) :220-228
[2]
BONE STRESS IN THE HORSE FORELIMB DURING LOCOMOTION AT DIFFERENT GAITS - A COMPARISON OF 2 EXPERIMENTAL METHODS [J].
BIEWENER, AA ;
THOMASON, J ;
GOODSHIP, A ;
LANYON, LE .
JOURNAL OF BIOMECHANICS, 1983, 16 (08) :565-576
[3]
Evolution during growth of the mechanical properties of the cortical bone in equine cannon-bones [J].
Bigot, G ;
Bouzidi, A ;
Rumelhart, C ;
MartinRosset, W .
MEDICAL ENGINEERING & PHYSICS, 1996, 18 (01) :79-87
[4]
Speed of sound measurements of the third metacarpal bone in young exercising thoroughbred racehorses [J].
Carstanjen, B ;
Lepage, OM ;
Hars, O ;
Langlois, P ;
Duboeuf, F ;
Amory, H .
BONE, 2003, 33 (03) :411-418
[5]
Equine third metacarpal bone assessment by quantitative ultrasound and dual energy X-ray absorptiometry:: An ex vivo study [J].
Carstanjen, B ;
Duboeuf, F ;
Detilleux, J ;
Lepage, OM .
JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2003, 50 (01) :42-47
[6]
Use of multisite quantitative ultrasonography for noninvasive assessment of bone in horses [J].
Carstanjen, B ;
Lepage, OM ;
Detilleux, J ;
Duboeuf, F ;
Amory, H .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2002, 63 (10) :1464-1469
[7]
Influence of density, elasticity, and structure on ultrasound transmission through trabecular bone cylinders [J].
Cavani, Francesco ;
Giavaresi, Gianluca ;
Fini, Milena ;
Bertoni, Laura ;
de Terlizzi, Francesca ;
Barkmann, Reinhard ;
Cane, Valerio .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (07) :1465-1472
[8]
DAVIES HMS, 1993, ACTA ANAT, V146, P148, DOI 10.1159/000147437
[9]
Methods for Assessing Bone Quality: A Review [J].
Donnelly, Eve .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2128-2138
[10]
Fatigue behavior of the equine third metacarpus: Mechanical property analysis [J].
Gibson, VA ;
Stover, SM ;
Martin, RB ;
Gibeling, TC ;
Willits, NH ;
Gustafson, MB ;
Griffin, LV .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) :861-868