Hydroxyapatite whiskers provide improved mechanical properties in reinforced polymer composites

被引:131
作者
Roeder, RK
Sproul, MM
Turner, CH
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46556 USA
[2] Indiana Univ Purdue Univ, Indianapolis, IN 46202 USA
[3] Indiana Univ, Med Ctr, Dept Orthoped Surg, Indianapolis, IN 46202 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2003年 / 67A卷 / 03期
关键词
orthopedics; bone substitutes; hydroxyapatite; polyethylene; anisotropy;
D O I
10.1002/jbm.a.10140
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Synthetic hydroxyapatite (HA) whiskers have been utilized as a new, biocompatible reinforcement for orthopedic biomaterials. High-density polyethylene (HDPE) was reinforced with either the synthesized HA whiskers or a commercially available spherical HA powder using a novel powder processing technique that facilitated uniform dispersion of the reinforcements in the matrix prior to compression molding. Composites were processed for up to 60 vol % HA whiskers and up to 50 vol % spherical HA. The mechanical properties of the new composite biomaterials were examined by uniaxial tensile tests. As expected, increased volume fraction of either reinforcement type over 0-50 vol % resulted in increased elastic modulus, a maximum in ultimate tensile stress, and decreased work to failure. Composites reinforced with HA whiskers had higher elastic modulus, ultimate tensile strength, and work to failure relative to composites reinforced with spherical HA. Thus, HA whisker-reinforced HDPE composites possessed improved mechanical properties over those reinforced with spherical HA. HA whisker-reinforced composites were anisotropic due to alignment of the whiskers in the matrix during processing. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:801 / 812
页数:12
相关论文
共 43 条
[1]
Agrawal CM, 2001, J BIOMED MATER RES, V55, P141, DOI 10.1002/1097-4636(200105)55:2<141::AID-JBM1000>3.0.CO
[2]
2-J
[3]
[Anonymous], 1986, LAW BONE REMODELLING
[4]
ORIENTATION OF APATITE IN SINGLE OSTEON SAMPLES AS STUDIED BY POLE FIGURES [J].
ASCENZI, A ;
BONUCCI, E ;
GENERALI, P ;
RIPAMONTI, A ;
ROVERI, N .
CALCIFIED TISSUE INTERNATIONAL, 1979, 29 (02) :101-105
[5]
A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[6]
HYDROXYAPATITE REINFORCED POLYETHYLENE - A MECHANICALLY COMPATIBLE IMPLANT MATERIAL FOR BONE-REPLACEMENT [J].
BONFIELD, W ;
GRYNPAS, MD ;
TULLY, AE ;
BOWMAN, J ;
ABRAM, J .
BIOMATERIALS, 1981, 2 (03) :185-186
[7]
Bonfield W., 1991, US Patent, Patent No. 5017627
[8]
Hearing results with the Dornhoffer ossicular replacement prostheses [J].
Dornhoffer, JL .
LARYNGOSCOPE, 1998, 108 (04) :531-536
[9]
MECHANOTRANSDUCTION AND THE FUNCTIONAL-RESPONSE OF BONE TO MECHANICAL STRAIN [J].
DUNCAN, RL ;
TURNER, CH .
CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) :344-358
[10]
Durucan C, 2000, J BIOMED MATER RES, V51, P726, DOI 10.1002/1097-4636(20000915)51:4<726::AID-JBM22>3.0.CO