Determination of soman and VX degradation products by an aspiration ion mobility spectrometry

被引:46
作者
Tuovinen, K [1 ]
Paakkanen, H [1 ]
Hänninen, O [1 ]
机构
[1] Univ Kuopio, Dept Physiol, SF-70211 Kuopio, Finland
关键词
ion mobility spectrometry (IMS); detection; chemical warfare agent degradation products; liquid matrices;
D O I
10.1016/S0003-2670(01)01063-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An aspiration type ion mobility spectrometry (IMS) has been used to determine chemical warfare agent (CWA) degradation products from liquid samples. This technique is based on ion mobility which depends on the molecular weight, charge and shape. With this method, it is possible to measure the mobility distribution of positive and negative ion clusters simultaneously in six different electrodes. Each measuring electrode determines a different portion of the ion mobility distribution formed within the cell's radioactive source. The strongest responses for all CWA degradation products and 2-propanol were seen in the order of sixth, fifth and second channels. On the basis of projection calculation, the fingerprints for 2-propanol and soman (GD; pinacolyl methylphosphonofluoridate) and VX o-ethyl-S-[2(diisopropylamino)ethyl] methylphosphonothioate) degradation products can be separated from each other. The detection levels for ethyl methylphosphonate (EMPA), pinacolyl methylphosphonate (PMPA), and ethylphosphonic acid (EPA) were 37.2 (37.2 mug/ml), 54.1 (54.1 mug/ml) and 55.1 ppm (55.1 mug/ml), respectively. However, the separation efficiency between different CWA degradation products was quite poor. The projections of these compounds were between 0.9976 and 0.9989, and this means that these fingerprints were identical. Thus, it is only possible to get one profile for all these degradation products of soman and VX. The data provided show that WS is suitable as a simple technique for screening of CWA degradation products. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 24 条
[1]   Separation and identification of some chemical warfare degradation products using electrospray high resolution ion mobility spectrometry with mass selected detection [J].
Asbury, GR ;
Wu, C ;
Siems, WF ;
Hill, HH .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :273-283
[2]   APPLICATION OF GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY TO THE ANALYSIS OF CHEMICAL WARFARE SAMPLES, FOUND TO CONTAIN RESIDUES OF THE NERVE AGENT SARIN, SULFUR MUSTARD AND THEIR DEGRADATION PRODUCTS [J].
BLACK, RM ;
CLARKE, RJ ;
READ, RW ;
REID, MTJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (02) :301-321
[3]  
CHEICANTE RL, 1995, J CAPILLARY ELECTROP, V2, P157
[4]   Analysis of chemical weapons decontamination waste from old ton containers from Johnston Atoll using multiple analytical methods [J].
Creasy, WR ;
Brickhouse, MD ;
Morrissey, KM ;
Stuff, JR ;
Cheicante, RL ;
Ruth, J ;
Mays, J ;
Williams, BR ;
O'Connor, R ;
Durst, HD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (13) :2157-2162
[5]  
EICEMAN GA, 1991, CRIT REV ANAL CHEM, V22, P17
[6]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO, P229
[7]   ION MOBILITY SPECTROMETRY [J].
HILL, HH ;
SIEMS, WF ;
STLOUIS, RH ;
MCMINN, DG .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :A1201-A1209
[8]  
KARPANOJA E, 2000, P NBC 2000 JYV FINL, P156
[9]   On-line solid-phase extraction liquid chromatography-continuous flow frit fast atom bombardment mass spectrometric and tandem mass spectrometric determination of hydrolysis products of nerve agents alkyl methylphosphonic acids by p-bromophenacyl derivatization [J].
Katagi, M ;
Tatsuno, M ;
Nishikawa, M ;
Tsuchihashi, H .
JOURNAL OF CHROMATOGRAPHY A, 1999, 833 (02) :169-179
[10]  
Kato T., 1992, P 4 INT S PROT CHEM, P103