Grafting of poly(ethylene oxide) to the surface of polyaniline films through a chlorosulfonation method and the biocompatibility of the modified films

被引:45
作者
Li, ZF [1 ]
Ruckenstein, E [1 ]
机构
[1] SUNY Buffalo, Dept Chem Engn, Buffalo, NY 14260 USA
关键词
polyaniline; poly(ethylene oxide); surface grafting; biocompatibility;
D O I
10.1016/S0021-9797(03)00606-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Poly(ethylene oxide) (PEO) could be grafted on the surface of polyaniline (PANI) films by chlorosulfonating the films with chlorosulfonic acid followed by reacting the modified films with PEO in a pyridine solution. The modified PANI films were examined by X-ray photoelectron spectroscopy and water droplet contact angles. The surface of the PEO grafted to hydrophobic PANI films became hydrophilic and the amounts of bovine serum albumin and human blood plasma platelet adsorbed onto it were decreased by more than 80%. For comparison purposes, and because the water wetting angle can be used as a measure of biocompatibility, wetting angle experiments have been also carried out for Pluronic triblock copolymer grafted to PANI and PEO or Pluronic molecules entrapped on the surfaces of PANI films. PANI was selected as substrate because one can easily change its surface properties by PEO grafting and because being conductive can be used as a sensor. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 45 条
[1]   Inhibition of corrosion of steels with the exploitation of conducting polymers [J].
Ahmad, N ;
MacDiarmid, AG .
SYNTHETIC METALS, 1996, 78 (02) :103-110
[2]   PREVENTION OF PROTEIN ADSORPTION AND PLATELET-ADHESION ON SURFACES BY PEO PPO PEO TRIBLOCK COPOLYMERS [J].
AMIJI, M ;
PARK, K .
BIOMATERIALS, 1992, 13 (10) :682-692
[3]   CONJUGATED POLYMER-FILMS FOR GAS SEPARATIONS [J].
ANDERSON, MR ;
MATTES, BR ;
REISS, H ;
KANER, RB .
SCIENCE, 1991, 252 (5011) :1412-1415
[4]   POLYANILINE - SOLUTIONS, FILMS AND OXIDATION-STATE [J].
ANGELOPOULOS, M ;
ASTURIAS, GE ;
ERMER, SP ;
RAY, A ;
SCHERR, EM ;
MACDIARMID, AG ;
AKHTAR, M ;
KISS, Z ;
EPSTEIN, AJ .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1988, 160 :151-163
[5]  
[Anonymous], 1982, BIOMATERIALS, V3, P181
[6]  
[Anonymous], 1976, POLYETHYLENE OXIDE
[7]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[8]   Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline-poly(n-butyl methacrylate) composites [J].
Castillo-Ortega, MM ;
Rodriguez, DE ;
Encinas, JC ;
Plascencia, M ;
Méndez-Velarde, FA ;
Olayo, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) :19-25
[9]   BLOOD-MATERIALS INTERACTIONS - THE MINIMUM INTERFACIAL FREE-ENERGY AND THE OPTIMUM POLAR APOLAR RATIO HYPOTHESES [J].
COLEMAN, DL ;
GREGONIS, DE ;
ANDRADE, JD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (04) :381-398
[10]  
Cui XY, 2001, J BIOMED MATER RES, V56, P261, DOI 10.1002/1097-4636(200108)56:2<261::AID-JBM1094>3.0.CO