Definition of the prostate in CT and MRI: A multi-observer study

被引:444
作者
Rasch, C
Barillot, I
Remeijer, P
Touw, A
van Herk, M
Lebesque, JV
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Huis, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[2] Ctr GF Leclerc, Dept Radiat Oncol, Dijon, France
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 01期
关键词
prostate cancer; 3D conformal radiotherapy; interobserver variation; intermodality variation; computer tomography; magnetic resonance imaging;
D O I
10.1016/S0360-3016(98)00351-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine, in three-dimensions, the difference between prostate delineation in magnetic resonance (MR) and computer tomography (CT) images for radiotherapy treatment planning. Patients and Methods: Three radiation oncologists, considered experts in the field, outlined the prostate without seminal vesicles both on CT, and axial, coronal, and sagittal MR images for 18 patients. To compare the resulting delineated prostates, the CT and MR scans were matched in three-dimensions using chamfer matching on bony structures. The volumes were measured and the interscan and interobserver variation was determined. The spatial difference between delineation in CT and MR (interscan variation) as well as the interobserver variation mere quantified and mapped three-dimensionally (3D) using polar coordinates. A urethrogram was performed and the location of the tip of the dye column was compared with the apex delineated in CT and MR images, Results: Interscan variation: CT volumes were larger than the axial MR volumes in 52 of 54 delineations. The average ratio between the CT and MR volumes was 1.4 (standard error of mean, SE: 0.04) which was significantly different from 1 (p < 0.005), Only small differences were observed between the volumes outlined in the various MR scans, although the coronal MR volumes were smallest. The CT derived prostate was 8 mm (standard deviation, SD: 6 mm) larger at the base of the seminal vesicles and 6 mm (SD 4 mm) larger at the apex of the prostate than the axial MRI. Similar figures were obtained for the CT and the other MRI scans. Interobserver variation: The average ratio between the volume derived by one observer for a particular scan and patient and the average volume was 0.95, 0.97, and 1.08 (SE 0.01) for the three observers, respectively. The 3D pattern of the overall observer variation (1 SD) for CT and axial MRI was similar and equal to 3.5 to 2.8 mm at the base of the seminal vesicles and 3 mm at the apex. Conclusion: CT-derived prostate volumes are larger than MR derived volumes, especially toward the seminal vesicles and the apex of the prostate, This interscan variation was found to be larger than the interobserver variation. Using MRI for delineation of the prostate reduces the amount of irradiated rectal wall, and could reduce rectal and urological complications. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 32 条
[1]   Reproducibility of prostate volume measurements from transrectal ultrasonography by an automated and a manual technique [J].
Aarnink, RG ;
DelaRosette, JJMCH ;
Debruyne, FMJ ;
Wijkstra, H .
BRITISH JOURNAL OF UROLOGY, 1996, 78 (02) :219-223
[2]   LOCALIZATION OF THE PROSTATIC APEX FOR RADIATION TREATMENT PLANNING [J].
ALGAN, O ;
HANKS, GE ;
SHAER, AH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (04) :925-930
[3]   Tumor and target delineation: Current research and future challenges [J].
AustinSeymour, M ;
Chen, GTY ;
Rosenman, J ;
Michalski, J ;
Lindsley, K ;
Goitein, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1041-1052
[4]   Complications after treatment with external-beam irradiation in early-stage prostate cancer patients: A prospective multiinstitutional outcomes study [J].
Beard, CJ ;
Propert, KJ ;
Rieker, PP ;
Clark, JA ;
Kaplan, I ;
Kantoff, PW ;
Talcott, JA .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (01) :223-229
[5]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[6]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[7]   Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms [J].
Boersma, LJ ;
van den Brink, M ;
Bruce, AM ;
Shouman, T ;
Gras, L ;
te Velde, A ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01) :83-92
[8]   PROSTATE-CANCER - COMPARISON OF RETROGRADE URETHROGRAPHY AND COMPUTED-TOMOGRAPHY IN RADIOTHERAPY PLANNING [J].
COX, JA ;
ZAGORIA, RJ ;
RABEN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05) :1119-1123
[9]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[10]   THE EFFECT OF DOSE ON LOCAL-CONTROL OF PROSTATE-CANCER [J].
HANKS, GE ;
MARTZ, KL ;
DIAMOND, JJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (06) :1299-1305