Frequency tracking of digital resonant filters for control of power converters connected to public distribution systems

被引:39
作者
Freijedo, F. D. [1 ]
Yepes, A. G. [1 ]
Malvar, J. [1 ]
Lopez, O. [1 ]
Fernandez-Comesana, P. [1 ]
Vidal, A. [1 ]
Doval-Gandoy, J. [1 ]
机构
[1] Univ Vigo, Dept Elect Technol, ETSEI, Vigo 36310, Pontevedra, Spain
关键词
STEADY-STATE ERROR; PHASE; PERFORMANCE; INVERTERS; HARMONICS; DESIGN;
D O I
10.1049/iet-pel.2010.0209
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Resonant filters implemented in the control of grid-connected power converters should adapt their coefficients in real time using a grid frequency estimation, for example, obtained by a phase-locked loop (PLL). Otherwise, perfect reference tracking and total disturbance rejection of ac signals are not achieved. An optimised implementation of resonant filters, which avoids shortcomings such as inaccurate pole placement and excessive resource consumption, is provided in this study. Normal grid frequency ranges of operation according to the Standard EN 50160 have been taken into account to optimise the trade-off between accuracy and resources. A shunt active power filter prototype (1 kVA rated) with frequency adaptive proportional + resonant current controller has been built to obtain the key figures. Main experimental tests prove that zero error in steady-state tracking of ac current references is achieved, even in the presence of significant frequency deviations (up to +/- 2 Hz). The influence of PLL estimations quality on the current controller is also experimentally verified (in practice, grid frequency estimations are not constant, so adaptive resonant filters are non-linear). More specifically, the sensitivity to ripple in estimations has been tested and its acceptable level is established. Finally, robustness in the presence of transients such as load changes, frequency steps and grid faults is proved.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 24 条
  • [1] [Anonymous], 2006, LECT POWER ELECT
  • [2] [Anonymous], 2007, EN50160 CENELEC
  • [3] BEST RE, 1999, PHASE LOCKED LOOPS D
  • [4] A phase tracking system for three phase utility interface inverters
    Chung, SK
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) : 431 - 438
  • [5] Doval J., 1998, 29 ANN IEEE POW EL S, V2, P1631
  • [6] A Signal-Processing Adaptive Algorithm for Selective Current Harmonic Cancellation in Active Power Filters
    Freijedo, Francisco D.
    Doval-Gandoy, Jesus
    Lopez, Oscar
    Fernandez-Comesana, Pablo
    Martinez-Penalver, Carlos
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (08) : 2829 - 2840
  • [7] A Generic Open-Loop Algorithm for Three-Phase Grid Voltage/Current Synchronization With Particular Reference to Phase, Frequency, and Amplitude Estimation
    Freijedo, Francisco D.
    Doval-Gandoy, Jesus
    Lopez, Oscar
    Acha, Enrique
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) : 94 - 107
  • [8] Fukuda S, 2001, IEEE T IND APPL, V37, P888, DOI 10.1109/28.924772
  • [9] Detailed analysis of closed-loop control of output-voltage harmonics in voltage-source inverters
    García-Cerrada, A
    Roncero-Sánchez, P
    García-González, P
    Feliú-Batlle, V
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2004, 151 (06): : 734 - 743
  • [10] Frequency-domain passivity-based current controller design
    Harnefors, L.
    Zhang, L.
    Bongiorno, M.
    [J]. IET POWER ELECTRONICS, 2008, 1 (04) : 455 - 465