Microfabricated multiphase packed-bed reactors: Characterization of mass transfer and reactions

被引:373
作者
Losey, MW
Schmidt, MA
Jensen, KF [1 ]
机构
[1] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[2] MIT, Microsyst Technol Labs, Cambridge, MA 02139 USA
关键词
D O I
10.1021/ie000523f
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A microchemical device has been built in silicon and glass by using microfabrication methods including deep-reactive-ion etch technology, photolithography, and multiple wafer bonding. The microchemical system consists of a microfluidic distribution manifold, a microchannel array, and a 25-mum microfilter for immobilizing solid particulate material within the reactor chip and carrying out different heterogeneous chemistries. Multiple reagent streams (specifically, gas and liquid streams) are mixed on-chip, and the fluid streams are brought into contact by a series of interleaved, high-aspect-ratio inlet channels. These inlet channels deliver the reactants continuously and cocurrently to 10 reactor chambers containing standard catalytic particles. The performance of the microfabricated "packed-bed" reactor is compared to that of traditional multiphase packed-bed reactors in terms of fluid flow regimes, pressure drop, and mass transfer. The hydrogenation of cyclohexene is used as a model reaction to measure the mass transfer resistances. Overall mass transfer coefficients (K(L)a) are measured to range from 5 to 15 s(-1)-nearly 2 orders of magnitude larger than values reported in the literature for standard laboratory-scale reactors.
引用
收藏
页码:2555 / 2562
页数:8
相关论文
共 27 条
[1]   High-pressure trickle-bed reactors: A review [J].
AlDahhan, MH ;
Larachi, F ;
Dudukovic, MP ;
Laurent, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1997, 36 (08) :3292-3314
[2]   Characterization of a time multiplexed inductively coupled plasma etcher [J].
Ayón, AA ;
Braff, R ;
Lin, CC ;
Sawin, HH ;
Schmidt, MA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (01) :339-349
[3]   Microfabricated silicon mixers for submillisecond quench-flow analysis [J].
Bökenkamp, D ;
Desai, A ;
Yang, X ;
Tai, YC ;
Marzluff, EM ;
Mayo, SL .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :232-236
[4]   SOME LIQUID HOLDUP EXPERIMENTAL-DATA IN TRICKLE-BED REACTORS FOR FOAMING AND NONFOAMING HYDROCARBONS [J].
CHARPENTIER, JC ;
FAVIER, M .
AICHE JOURNAL, 1975, 21 (06) :1213-1218
[5]   Microreactors for chemical synthesis [J].
DeWitt, SH .
CURRENT OPINION IN CHEMICAL BIOLOGY, 1999, 3 (03) :350-356
[6]   Characterization of mixing in micromixers by a test reaction:: Single mixing units and mixer arrays [J].
Ehrfeld, W ;
Golbig, K ;
Hessel, V ;
Löwe, H ;
Richter, T .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (03) :1075-1082
[7]  
Ehrfeld W, 1998, TOP CURR CHEM, V194, P233
[8]  
EIGENBERGER G, 1982, ACS SYM SER, V196, P133
[9]  
Fogler H.S., 1999, ELEMENTS CHEM REACTI
[10]   Microchemical systems: Status, challenges, and opportunities [J].
Jensen, KF .
AICHE JOURNAL, 1999, 45 (10) :2051-2054