Early free tissue transfer for extremity reconstruction following high-voltage electrical burn injuries

被引:30
作者
Saint-Cyr, Michel [1 ,2 ]
Daigle, Jean-Pierre [2 ]
机构
[1] UT SW Med Ctr, Dept Plast Surg, Dallas, TX 75390 USA
[2] Univ Montreal, Hop Hotel Dieu, Ctr Grands Brules, Ctr Hosp,Dept Surg,Div Plast & Reconstruct Surg, Montreal, PQ, Canada
关键词
electrical burn; extremity; free flap; microsurgery; limb salvage;
D O I
10.1055/s-2008-1078697
中图分类号
R61 [外科手术学];
学科分类号
摘要
We compared the effectiveness of free tissue transfer in repairing high-voltage electrical extremity injuries with conventional multistage procedures. Patients were matched for age, sex, level of injury, voltage, and burn surface area; results were compared using the paired Student t test. Free tissue transfer was performed a mean of 19.1 +/- 10.6 days after the injury occurred, and definitive wound closure and limb salvage were achieved in 87.5% of patients after a mean of 23.0 +/- 9.1 days after the injury. The overall flap survival rate was 80% (13 of 15 flaps). Three flaps failed, two of which were lower-limb flaps at the knee level used for patients with injuries to both upper and lower limbs. Both patients required upper and lower proximal ipsilateral limb amputations. One upper-extremity flap failed after pedicle avulsion 4 days after surgery, but a second free tissue transfer was successful in salvaging this limb 4 days later. The number of surgeries, time required to achieve wound closure, and length of hospitalization were all statistically significantly lower in the free flap group compared with those in the conventional treatment group.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 19 条
[1]
ELECTRICAL BURN INJURY TO THE UPPER EXTREMITY [J].
ACHAUER, B ;
APPLEBAUM, R ;
VANDERKAM, VM .
BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (05) :331-340
[2]
Principles of microvascular reconstruction in burn and electrical burn injuries [J].
Baumeister, S ;
Köller, M ;
Dragu, A ;
Germann, G ;
Sauerbier, M .
BURNS, 2005, 31 (01) :92-98
[3]
The combined scapular/parascapular flap for the treatment of extensive electrical burns of the upper extremity [J].
Cerkes, N ;
Erer, M ;
Sirin, F .
BRITISH JOURNAL OF PLASTIC SURGERY, 1997, 50 (07) :501-506
[4]
EARLY FREE-FLAP COVERAGE OF ELECTRICAL AND THERMAL BURNS [J].
CHICK, LR ;
LISTER, GD ;
SOWDER, L .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (06) :1013-1019
[5]
CIERNY G, 1983, CLIN ORTHOP RELAT R, P54
[6]
THE EARLY USE OF FREE FLAPS IN BURNS [J].
GROTTING, J ;
WALKINSHAW, M .
ANNALS OF PLASTIC SURGERY, 1985, 15 (02) :127-131
[7]
FREE LATISSIMUS DORSI MUSCLE FLAP COVERAGE OF AN ELECTRICAL BURN OF THE LOWER-EXTREMITY [J].
HAGAN, KF ;
BUNCKE, HJ ;
GONZALEZ, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1982, 69 (01) :125-128
[8]
MAINTENANCE OF STUMP LENGTH OF BOTH UPPER EXTREMITIES AFTER SEVERE ELECTRICAL BURN INJURY [J].
KOMURCU, F ;
STUFFER, M ;
HUSSL, H ;
ANDERL, H .
BURNS, 1990, 16 (03) :227-229
[9]
KONIGOVA R, 1998, DISASTERS, V11, P156
[10]
EMERGENCY FREE FLAPS TO THE UPPER EXTREMITY [J].
LISTER, G ;
SCHEKER, L .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (01) :22-28