Aortic valve replacement with the St. Jude Medical prosthesis and fixed dose anticoagulation

被引:8
作者
Katircioglu, SF [1 ]
Yamak, B [1 ]
Ulus, AT [1 ]
Iscan, HZ [1 ]
Mavitas, B [1 ]
Tasdemir, O [1 ]
机构
[1] Turkiye Yuksek Ihtisas Hosp, Dept Cardiovasc Surg, TR-06100 Sihhiye, Ankara, Turkey
关键词
D O I
10.1111/j.1540-8191.1997.tb00152.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Over a 10-year period, between 1986 and 1996, 865 patients underwent primary aortic valve replacement (AVR) with the St. Jude Medical mechanical prosthesis. Patients who had undergone valve replacement with a different type of prosthesis previously were excluded from this study. Patient age ranged from 11 to 79 years. The mean age was 42.9 +/- 14.54. The gender distribution was 396 men (45.8%) and 469 women (54.2%). All patients received 2.5 mg/day Coumadin after extubation. A combination of the antiagregant therapy (Dypridamole 3X 75 mg/day, Asprine 100 mg/day) was added after removal of the chest tubes. The dosage of Coumadin was maintained constant regardless of the prothrombin time (PT) or cardiac rhythm. There were 101 valve-related complications (4.2% per patient year [ppy]) occurring in the late follow-up period. Of these complications; 38 were anticoagulant-related hemorrhage (1.58% ppy), 3 were paravalvular leak (0.12% ppy), and 36 were thromboembolism (1.4% ppy). There were 24 reoperations (0.99% ppy) and 17 late deaths. The linearized late mortality rate was 0.7% ppy. Long-term survival estimates at 5 and 10 years were 97.14 +/- 0.82% and 94.86 +/- 1.54%, respectively. We conclude from the data that the St. Jude Medical valve may allow the use of a low level of anticoagulation. This study shows that fixed dose oral anticoagulation does not increase the rate of thromboembolism in patients with the St. Jude aortic valve. This protocol does not result in reduction of bleeding complications, however.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 26 条
[1]
MECHANICAL CARDIAC VALVULAR PROSTHESES [J].
AKINS, CW .
ANNALS OF THORACIC SURGERY, 1991, 52 (01) :161-172
[2]
CLINICAL-PERFORMANCE OF ST-JUDE AND MEDTRONIC-HALL PROSTHESES - A RANDOMIZED COMPARATIVE-STUDY [J].
ANTUNES, MJ .
ANNALS OF THORACIC SURGERY, 1990, 50 (05) :743-747
[3]
ARMENTI F, 1987, J THORAC CARDIOV SUR, V94, P733
[4]
10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS [J].
AROM, KV ;
NICOLOFF, DM ;
KERSTEN, TE ;
NORTHRUP, WF ;
LINDSAY, WG ;
EMERY, RW .
ANNALS OF THORACIC SURGERY, 1989, 47 (06) :831-837
[5]
BAUDET EM, 1985, J THORAC CARDIOV SUR, V90, P137
[6]
BURCKHARDT D, 1988, CIRCULATION, V78, P18
[7]
A 6 YEAR EXPERIENCE WITH THE ST-JUDE MEDICAL VALVE - HEMODYNAMIC PERFORMANCE, SURGICAL RESULTS, BIOCOMPATIBILITY AND FOLLOW-UP [J].
CZER, LSC ;
MATLOFF, J ;
CHAUX, A ;
DEROBERTIS, M ;
YOGANATHAN, A ;
GRAY, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (04) :904-912
[8]
CZER LSC, 1990, J THORAC CARDIOVASC, V100, P167
[9]
DURABILITY AND LOW THROMBOGENICITY OF THE ST-JUDE MEDICAL VALVE AT 5-YEAR FOLLOW-UP [J].
DUNCAN, JM ;
COOLEY, DA ;
REUL, GJ ;
OTT, DA ;
HALLMAN, GL ;
FRAZIER, OH ;
LIVESAY, JJ ;
WALKER, WE ;
ADAMS, PR .
ANNALS OF THORACIC SURGERY, 1986, 42 (05) :500-505
[10]
EARLY AND LATE-PHASE EVENTS AFTER VALVE-REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS IN 1200 PATIENTS [J].
FERNANDEZ, J ;
LAUB, GW ;
ADKINS, MS ;
ANDERSON, WA ;
CHEN, C ;
BAILEY, BM ;
NEALON, LM ;
MCGRATH, LB .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (02) :394-407