Effect of the homogeneity of the column set on the performance of a simulated moving bed unit I. Theory

被引:26
作者
Mihlbachler, K
Fricke, J
Yun, T
Seidel-Morgenstern, A
Schmidt-Traub, H
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
[3] Univ Magdeburg, Dept Chem Engn, D-39106 Magdeburg, Germany
[4] Univ Dortmund, Dept Chem Engn, D-4600 Dortmund, Germany
关键词
simulated moving bed chromatography; retention factors; porosity;
D O I
10.1016/S0021-9673(00)00935-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although it is impossible to manufacture identical columns for use in a simulated moving bed (SMB) process, theoretical studies assume that all the columns in an SMB unit have identical characteristics. In practice, calculations in modeling and optimization studies are made with the average values of each column parameter set. In this report, the effects on SMB process performance caused by column-to-column fluctuations of the parameters are discussed, As a first step, we show how the differences in porosity of the columns may be taken into account with a revised set of separation conditions. Reductions in the purity of the extract and the raffinate streams are quantitatively related to the column-to-column fluctuations of the retention times of the two components arising from these porosity differences. For the sake of simplicity, the discussion first addresses the case of a four-column SMB operating under linear conditions. Then, the scope is extended to the cases of SMB units incorporating several columns in each section and to SMB units operating under nonlinear conditions. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:49 / 70
页数:22
相关论文
共 26 条
[1]   Enantiomers separation by simulated moving bed chromatography - Non-instantaneous equilibrium at the solid-fluid interface [J].
Azevedo, DCS ;
Pais, LS ;
Rodrigues, AE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 865 (1-2) :187-200
[2]  
BALANNEC B, 1993, PREPARATIVE PRODUCTI, P301
[3]  
BROUGHTON DB, 1970, CHEM ENG PROG, V66, P70
[4]  
Broughton DB, 1961, U. S. Patent, Patent No. [2,985,589, 2985589]
[5]   COMPLETE DESIGN OF A SIMULATED MOVING-BED [J].
CHARTON, F ;
NICOUD, RM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 702 (1-2) :97-112
[6]   PREPARATIVE RESOLUTION OF PRAZIQUANTEL ENANTIOMERS BY SIMULATED COUNTERCURRENT CHROMATOGRAPHY [J].
CHING, CB ;
LIM, BG ;
LEE, EJD ;
NG, SC .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02) :215-219
[7]   DESIGN AND PERFORMANCE OF A SIMULATED COUNTERCURRENT MOVING-BED SEPARATOR [J].
FISH, BB ;
CARR, RW ;
ARIS, R .
AICHE JOURNAL, 1993, 39 (11) :1783-1790
[8]  
GUAN H, 1996, J CHROMATOGR A, V731, P41
[9]  
Guiochon G., 1994, FUNDAMENTALS NONLINE
[10]   A SIMULATED MOVING-BED ADSORBER FOR THE SEPARATION OF TRICOMPONENTS [J].
HASHIMOTO, K ;
SHIRAI, Y ;
ADACHI, S .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1993, 26 (01) :52-56