Nasal lavage biomarkers:: Effects of water damage and microbial growth in an office building

被引:57
作者
Wålinder, R
Wieslander, G
Norbäck, D
Wessen, B
Venge, P
机构
[1] Univ Uppsala Hosp, Dept Med Sci Ocupat & Environm Med, SE-75185 Uppsala, Sweden
[2] Pegasus Lab, Uppsala, Sweden
[3] Univ Uppsala Hosp, Dept Med Sci Clin Chem, SE-75185 Uppsala, Sweden
[4] Univ Uppsala Hosp, Asthma Res Ctr, SE-75185 Uppsala, Sweden
来源
ARCHIVES OF ENVIRONMENTAL HEALTH | 2001年 / 56卷 / 01期
关键词
dampness; microbial growth; nasal lavage biomarkers; office building;
D O I
10.1080/00039890109604052
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Selected nasal symptoms were studied in personnel who worked in a damp office building that had microbial growth (including Stachybotrys sp.) in mineral fiber insulation and gypsum board. There were also signs of dampness in the floor. Clinical examinations included nasal lavage and peak expiratory flow measurements in 12 subjects in the damp building; an additional 8 subjects in a control building (i.e., no signs of dampness or microbial growth) were also examined. Hygienic air measurements of microorganisms and volatile organic compounds were performed in both buildings. The concentrations of eosinophil cationic protein, myeloperoxidase, and albumin, and the number of subjects with eosinophils in lavage fluid, were higher among office workers in the damp building than among controls. The damp building had greater amounts of total molds and bacteria in its construction than the building materials in nondamp buildings. In addition, an increase of 2-ethyl-1-hexanol in the indoor air was detected in the damp building-a sign of dampness-related alkaline degradation of diethyl-hexyl phthalate in polyvinyl chloride floor coatings. In conclusion, the results of this study indicate that exposures in a damp office building may cause an inflammatory nasal mucosal response. The results also support conclusions of earlier studies, indicating that building dampness is related to respiratory inflammation.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 49 条
[1]   Work related impairment of nasal function in Swedish woodwork teachers [J].
Ahman, M ;
Holmstrom, M ;
Cynkier, I ;
Soderman, E .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1996, 53 (02) :112-117
[2]   ASTHMATIC SYMPTOMS AND INDOOR LEVELS OF MICROORGANISMS AND HOUSE-DUST MITES [J].
BJORNSSON, E ;
NORBACK, D ;
JANSON, C ;
WIDSTROM, J ;
PALMGREN, U ;
STROM, G ;
BOMAN, G .
CLINICAL AND EXPERIMENTAL ALLERGY, 1995, 25 (05) :423-431
[3]   DAMP HOUSING AND ADULT RESPIRATORY SYMPTOMS [J].
BRUNEKREEF, B .
ALLERGY, 1992, 47 (05) :498-502
[4]   HOME DAMPNESS AND RESPIRATORY MORBIDITY IN CHILDREN [J].
BRUNEKREEF, B ;
DOCKERY, DW ;
SPEIZER, FE ;
WARE, JH ;
SPENGLER, JD ;
FERRIS, BG .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05) :1363-1367
[5]   TRYPTASE LEVELS IN NASAL-LAVAGE FLUID AS AN INDICATOR OF THE IMMEDIATE ALLERGIC RESPONSE [J].
CASTELLS, M ;
SCHWARTZ, LB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1988, 82 (03) :348-355
[6]   Correlation between the prevalence of certain fungi and sick building syndrome [J].
Cooley, JD ;
Wong, WC ;
Jumper, CA ;
Straus, DC .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 55 (09) :579-584
[7]   AIRBORNE OUTBREAK OF TRICHOTHECENE TOXICOSIS [J].
CROFT, WA ;
JARVIS, BB ;
YATAWARA, CS .
ATMOSPHERIC ENVIRONMENT, 1986, 20 (03) :549-552
[8]   NATURAL-HISTORY OF BRONCHIAL-ASTHMA IN CHILDHOOD - A PROSPECTIVE-STUDY FROM BIRTH UP TO 12-14 YEARS OF AGE [J].
CRONER, S ;
KJELLMAN, NIM .
ALLERGY, 1992, 47 (02) :150-157
[9]   ADVERSE HEALTH-EFFECTS AMONG ADULTS EXPOSED TO HOME DAMPNESS AND MOLDS [J].
DALES, RE ;
BURNETT, R ;
ZWANENBURG, H .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (03) :505-509
[10]   RESPIRATORY HEALTH-EFFECTS OF HOME DAMPNESS AND MOLDS AMONG CANADIAN CHILDREN [J].
DALES, RE ;
ZWANENBURG, H ;
BURNETT, R ;
FRANKLIN, CA .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (02) :196-203