Performances of an ultralow frequency vertical pre-isolator for the VIRGO seismic attenuation chains

被引:18
作者
DeSalvo, R
DiVirgilio, A
Errico, A
Feng, GT
Ferrante, I
Frasconi, F
Gaddi, A
Gennai, A
Gennaro, G
Giazotto, A
Holloway, L
Losurdo, G
Maggiore, M
Mancini, S
Mazzoni, M
Palla, F
Bao, PH
Paoletti, F
Pasqualetti, A
Passaquieti, R
Passuello, D
Poggiani, R
Popolizio, P
Raffaelli, F
Righetti, D
Ruberti, R
Rubino, V
Ruggi, P
Stanga, R
Taddei, R
Valentini, R
Vicere, A
Winterflood, J
Zhang, Z
Bernardini, M
Bozzi, A
Braccini, S
Bradaschia, C
Casciano, C
Cella, GC
Ciampa, A
Curci, G
D'Ambrosio, E
Dattilo, V
DeCarolis, GC
Delapierre, A
机构
[1] Ist Nazl Fis Nucl, Sez Pisa, I-56010 Pisa, Italy
[2] Tecnomare, I-30124 Venice, Italy
[3] Consorzio Pisa Ric, I-56127 Pisa, Italy
[4] PROMEC, I-56031 Bientina, Italy
[5] Univ Illinois, Dept Phys, Urbana, IL 61801 USA
[6] Scuola Normale Super Pisa, I-56100 Pisa, Italy
[7] Univ Florence, Dipartimento Astron, I-50100 Florence, Italy
[8] Galli & Morelli, I-55100 Acquacalda, Italy
[9] Univ Pisa, Dipartimento Fis, I-56100 Pisa, Italy
[10] Univ Pisa, Fac Ingn, I-56100 Pisa, Italy
[11] Univ Western Australia, Dept Phys, Perth, WA 6009, Australia
[12] Inst Natl Sci Appl, F-69621 Villeurbanne, France
关键词
seismic isolation; gravitational waves; mechanical attenuation;
D O I
10.1016/S0168-9002(98)00684-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An ultralow resonant frequency vertical seismic activity attenuation filter prototype has been designed and built as the vertical component of a Pre-Isolation Stage (PIS) for low-frequency Seismic Attenuation (SA) chains. The task of the PIS is to reduce the excitation of the chain payload's resonant residual motions. A characterization and the performance of the prototype are reported along with some design considerations. An attenuation of 45 dB has been achieved in the region of interest (the SA chain resonant frequency band) and an upgrade to more than 50 dB attenuation is easily achievable, Tests of active feedback loop attenuation driven by electro magnetic actuators and controlled by a Digital Signal Processor reading a precision vertical accelerometer have been successfully performed. The filter also effectively acts as a precision positioner for the suspended payload, (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:316 / 335
页数:20
相关论文
共 19 条
  • [1] [Anonymous], VIRTREPIS4600142
  • [2] Extending the VIRGO gravitational wave detection band down to a few Hz: metal blade springs and magnetic antisprings
    Beccaria, M
    Bernardini, M
    Bougleux, E
    Braccini, S
    Bradaschia, C
    Casciano, C
    Cella, G
    Cucco, E
    DAmbrosio, E
    DeCarolis, G
    DelFabbro, R
    DeSalvo, R
    DiVirgilio, A
    Ferrante, I
    Fidecaro, F
    Flaminio, R
    Gaddi, A
    Gennai, A
    Gennaro, G
    Giazotto, A
    Holoway, L
    LaPenna, P
    Losurdo, G
    Malik, S
    Mancini, S
    Nicolas, J
    Palla, F
    Pan, HB
    Paoletti, F
    Pasqualetti, A
    Passuello, D
    Poggiani, R
    Popolizio, P
    Raffaelli, F
    Vicere, A
    Waharte, F
    Zhang, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 394 (03) : 397 - 408
  • [3] The creep problem in the VIRGO suspensions: a possible solution using Maraging steel
    Beccaria, M
    Bernardini, M
    Braccini, S
    Bradaschia, C
    Cagnoli, G
    Casciano, C
    Cella, G
    Cuoco, E
    Dattilo, V
    De Carolis, G
    De Salvo, R
    Di Virgilio, A
    Feng, GT
    Ferrante, I
    Fidecaro, F
    Frasconi, F
    Gaddi, A
    Gammaitoni, L
    Gennai, A
    Giazotto, A
    Holloway, L
    Kovalik, J
    La Penna, P
    Losurdo, G
    Malik, S
    Mancini, S
    Marchesoni, F
    Nicolas, J
    Palla, F
    Pan, HB
    Paoletti, F
    Pasqualetti, A
    Passuello, D
    Poggiani, R
    Popolizio, P
    Punturo, M
    Raffaelli, F
    Rubino, V
    Valentini, R
    Vicere, A
    Waharte, F
    Zhang, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 404 (2-3) : 455 - 469
  • [4] BOZZI A, 1997, VIRTREPIS4600130
  • [5] Seismic vibrations mechanical filters for the gravitational waves detector VIRGO
    Braccini, S
    Bradaschia, C
    DelFabbro, R
    DiVirgilio, A
    Ferrante, I
    Fidecaro, F
    Flaminio, R
    Gennai, A
    Giassi, A
    Giazotto, A
    Gorini, G
    Losurdo, G
    Palla, F
    Pasqualetti, A
    Passuello, D
    Poggiani, R
    Torelli, G
    Zhang, Z
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08) : 2899 - 2902
  • [6] BRACCINI S, 1997, REV SCI INSTRUM, V68, P3094
  • [7] BRACCINI S, 1996, VIRNOTPIS4600108
  • [8] BRACCINI S, 1996, VIRNOTPIS4600109
  • [9] CELLA G, 1997, VIRTREPIS4600125
  • [10] CELLA GC, VIRNOTPIS1390091