Fibrin sealant: A novel method of fixation for an implantable ultrasonic microDoppler probe

被引:21
作者
Bill, TJ [1 ]
Foresman, PA [1 ]
Rodeheaver, GT [1 ]
Drake, DB [1 ]
机构
[1] Univ Virginia, Dept Plast Surg, Hlth Sci Ctr, Charlottesville, VA 22908 USA
关键词
fibrin sealant; Doppler probe; microsurgery; postoperative monitoring;
D O I
10.1055/s-2001-14517
中图分类号
R61 [外科手术学];
学科分类号
摘要
While free tissue transfer affords the reconstructive microvascular surgeon the ability to provide coverage for complex wounds, the postoperative monitoring of these flaps continues to evolve. The most recent advance has been the development of an implantable microDoppler probe to provide an early warning signal for vascular obstruction. The current system relies on the use of a silicone cuff to secure a l-mm probe to the out-flow vein. The release force to remove the probe from the cuff is reported to be 1/10 of a pound (45 g). A disadvantage of this system is the need for a circumferential, relatively in elastic device around the vein. Should the cuff be too tightly secured to the vein, the potential for outflow obstruction exists. Moreover, if the probe is not well-approximated to the vein, no signal is produced. Finally, the fact that a foreign body remains in the wound after completion of the monitoring period remains a concern. The authors have investigated a new method to adhere the probe, using a commercially available fibrin sealant. The use of this biocompatible substance has the potential to obviate the need for the current method of fixation, and the associated concerns.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 27 条
[1]  
Akizuki Shaw, 1997, Bulletin Hospital for Joint Diseases, V56, P222
[2]  
BERGEL S, 1909, DEUT MED WOCHENSCHR, V35, P633
[3]   FIBRIN GLUE [J].
BRENNAN, M .
BLOOD REVIEWS, 1991, 5 (04) :240-244
[4]   MONITORING IN MICROVASCULAR SURGERY [J].
FURNAS, H ;
ROSEN, JM .
ANNALS OF PLASTIC SURGERY, 1991, 26 (03) :265-272
[5]  
Gyo K, 1997, Ear Nose Throat J, V76, P316
[6]   A review of 716 consecutive free flaps for oncologic surgical defects: Refinement in donor-site selection and technique [J].
Hidalgo, DA ;
Disa, JJ ;
Cordeiro, PG ;
Hu, QY .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (03) :722-732
[7]   ALVEOLAR RIDGE AUGMENTATION WITH HYDROXYLAPATITE USING FIBRIN SEALANT FOR FIXATION .1. AN EXPERIMENTAL-STUDY [J].
HOTZ, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 20 (04) :204-207
[8]   Clinical, outcome of digital replantation using the fibrin glue-assisted microvascular anastomosis technique [J].
Isogai, N ;
Cooley, BC ;
Kamiishi, H .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (05) :573-575
[9]  
JONES NF, 1992, CLIN PLAST SURG, V19, P783
[10]   The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants [J].
Kind, GM ;
Buntic, RF ;
Buncke, GM ;
Cooper, TM ;
Siko, PP ;
Buncke, HJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (05) :1268-1273