Estimating the composition of tomato juice products by near infrared spectroscopy

被引:15
作者
Goula, AM [1 ]
Adamopoulos, KG [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Engn, Dept Chem Engn, Lab Food Proc Engn, Thessaloniki 54124, Greece
关键词
tomato juice; near infrared reflectance spectroscopy; moisture; sugars; acid; protein; salt;
D O I
10.1255/jnirs.360
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The use of near infrared (NIR) reflectance spectroscopy for the rapid and accurate measurement of moisture, sugar, acid, protein and salt was explored in a diverse group of tomato juice products. Partial and overall calibrations were performed on four different tomato juice products. Partial calibrations for each product included samples of the specific product, whereas overall calibration used samples of all the products. Samples were analysed employing traditional chemical methods and scanned using an Instalab 600-Dickey-John NIR apparatus to obtain NIR spectra. Calibrations were achieved with the use of multilinear regression between chemical and spectral data from each calibration data set. A separate set of samples was used to validate the calibrations. Linear regression was applied to compare the results obtained by NIR spectroscopy for all constituents of the validation set with those obtained by the reference methods. In addition, the root mean square error of prediction (RMSEP), the bias and the correlation coefficients (r and r') were calculated. All of the statistical parameters were better with overall than with partial calibrations. Prediction ability of overall calibration was very good for all the constituents. r and r' values were higher than 0.9488 and 0.9453, respectively, RMSEP values were smaller than 0.1067, whereas bias varied from -0.020 to 0.016. The partial calibrations are considerable less variable with the correlation coefficients r and r' ranged from 0.8890 to 0.9477 and from 0.7202 to 0.8518, respectively, RMSEP varied from 0.0647 to 0.4942 and bias from -0.365 to 0.071. NIR measurement as performed by the Dickey-John Analyser was proved a rapid and accurate method for analysis of tomato juice samples and may be used as a replacement for conventional expensive and time-consuming wet chemistry methods.
引用
收藏
页码:123 / 136
页数:14
相关论文
共 19 条
[1]   Quality control during processing of feta cheese - NIR application [J].
Adamopoulos, KG ;
Goula, AM ;
Petropakis, HJ .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2001, 14 (04) :431-440
[2]  
[Anonymous], 1998, J NEAR INFRARED SPEC
[3]  
*AOAC, 1980, OFF METH AN ASS OFF, P538
[4]   NIR spectroscopy: a rapid-response analytical tool [J].
Blanco, M ;
Villarroya, I .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (04) :240-250
[5]  
DAVIES AMC, 1987, INT J FOOD SCI TECH, V22, P191
[6]  
*DICK JOHN CORP, 1996, INST REGR DAT COLL P
[7]   NEAR-INFRARED MEASUREMENT OF RELATIVE AND ABSOLUTE-HUMIDITY THROUGH DETECTION OF WATER ADSORBED ON A SILICA-GEL LAYER [J].
FONG, A ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1139-1146
[8]  
Goose P.G., 1964, TOMATO PASTE PUREE J, V1st
[9]  
Gould W.A, 1974, TOMATO PRODUCTION PR
[10]   Moisture, solids-non-fat and fat analysis in butter by near infrared spectroscopy [J].
Hermida, M ;
Gonzalez, JM ;
Sanchez, M ;
Rodriguez-Otero, JL .