The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model

被引:19
作者
Sinicropi, SA
Su, BW
Raia, FJ
Parisien, M
Strauch, RJ
Rosenwasser, MP
机构
[1] New York Orthoped Hosp, New York, NY USA
[2] New York Presbyterian Hosp, Dept Pathol, New York, NY USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2005年 / 30A卷 / 02期
关键词
II plate; distal radius fractures; titanium metallosis;
D O I
10.1016/j.jhsa.2004.08.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. Methods: An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Results: Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-Al6-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Conclusions: Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants. Copyright (c) 2005 by the American Society for Surgery of the Hand.
引用
收藏
页码:300 / 307
页数:8
相关论文
共 35 条
[1]
METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[3]
Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[4]
TITANIUM IMPLANTS PERMANENTLY PENETRATING HUMAN-SKIN [J].
BRANEMARK, PI ;
ALBREKTSSON, T .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1982, 16 (01) :17-21
[5]
TITANIUM LINES - A MANIFESTATION OF METALLOSIS AND TISSUE-RESPONSE TO TITANIUM-ALLOY MEGAPROSTHESES AT THE KNEE [J].
BREEN, DJ ;
STOKER, DJ .
CLINICAL RADIOLOGY, 1993, 47 (04) :274-277
[6]
Buly R L, 1992, J Arthroplasty, V7, P315, DOI 10.1016/0883-5403(92)90056-V
[7]
Büttner-Janz K, 2002, UNFALLCHIRURG, V105, P278, DOI 10.1007/s001130100329
[8]
Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[9]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[10]
Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures [J].
Chiang, PP ;
Roach, S ;
Baratz, ME .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (04) :724-728