Plating of the distal radius

被引:109
作者
Nana, AD [1 ]
Joshi, A [1 ]
Lichtman, DM [1 ]
机构
[1] JPS Hlth Network, Dept Orthopaed Surg, Ft Worth, TX 76104 USA
关键词
D O I
10.5435/00124635-200505000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal radius fractures are common injuries that can be treated by a variety of methods. Restoration of the distal radius anatomy within established guidelines yields the best short- and long-term results. Guidelines for acceptable reduction are (1) radial shortening < 5 mm, (2) radial inclination > 15°, (3) sagittal tilt on lateral projection between 150 dorsal tilt and 20° volar tilt, (4) intra-articular step-off < 2 mm of the radiocarpal joint, and (5) articular incongruity < 2 mm of the sigmoid notch of the distal radius. Treatment options range from closed reduction and immobilization to open reduction with plates and screws; options are differentiated based on their ability to reinforce and stabilize the three columns of the distal radius and ulna. Plating allows direct restoration of the anatomy, stable internal fixation, a decreased period of immobilization, and early return of wrist function. Buttress plates reduce and stabilize vertical shear intra-articular fractures through an antiglide effect, whereas conventional and locking plates address metaphyseal comminution and/or preserve articular congruity/reduction. With conventional and locking plates, intra-articular fractures are directly reduced; with buttress plates, the plate itself helps reduce the intra-articular fracture. Complications associated with plating include tendon irritation or rupture and the need for plate removal.
引用
收藏
页码:159 / 171
页数:13
相关论文
共 44 条
[1]
Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility [J].
Andersen, DJ ;
Blair, WF ;
Steyers, CM ;
Adams, BD ;
ElKhouri, GY ;
Brandser, EA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04) :574-582
[2]
[Anonymous], 1996, HAND SURG UPDATE
[3]
Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[4]
Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[5]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[6]
Displaced intra-articular fractures of the distal aspect of the radius - Long-term results in young adults after open reduction and internal fixation [J].
Catalano, LW ;
Cole, RJ ;
Gelberman, RH ;
Evanoff, BA ;
Gilula, LA ;
Borrelli, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1290-1302
[7]
Radial artery pseudoaneurysm complication from use of AO/ASIF volar distal radius plate: A case report [J].
Dao, KD ;
Venn-Watson, E ;
Shin, AY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (03) :448-453
[8]
FERNANDEZ DL, 1999, J HAND SURG, V24, P102
[9]
Initial experience with the Forte plate for dorsally displaced distal radius fractures [J].
Finsen, V ;
Aasheim, T .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (06) :445-448
[10]
Treatment of displaced intra-articular fractures of the distal end of the radius with plates [J].
Fitoussi, F ;
Ip, WY ;
Chow, SP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1303-1312