2-Year Follow-Up of a Randomized Controlled Trial of Everolimus- and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice

被引:157
作者
Smits, Pieter C. [1 ]
Kedhi, Elvin [1 ]
Royaards, Kees-Jan [1 ]
Joesoef, Kaiyum Sheik [1 ]
Wassing, Jochem [1 ]
Rademaker-Havinga, Tessa A. M.
McFadden, Eugene [1 ]
机构
[1] Maasstad Ziekenhuis, Dept Cardiol, NL-3075 EA Rotterdam, Netherlands
关键词
drug-eluting stent; myocardial infarction; stent thrombosis; ARTERY-DISEASE;
D O I
10.1016/j.jacc.2011.02.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to compare the safety and efficacy of the Xience V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) with the Taxus Liberte (Boston Scientific, Natick, Massachusetts) paclitaxel-eluting stent (PES) at 2-year follow-up. Background COMPARE (Comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: a randomized open label trial) demonstrated a superior clinical outcome of EES over PES at 1 year in all comers. Whether this superiority is maintained after discontinuation, at 12 months, of dual antiplatelet therapy is unclear. Methods Patients undergoing percutaneous coronary intervention with limited exclusion criteria were randomly allocated to EES or PES. The 2-year pre-specified endpoints are composites of safety and efficacy and stent thrombosis. Results Follow-up was completed in 1,795 of 1,800 patients (99.7%). The groups had similar baseline characteristics. At 2 years, significantly fewer EES patients took dual antiplatelet therapy (11.4% vs. 15.4%, p = 0.02). The primary composite of all death, nonfatal myocardial infarction, and target vessel revascularization occurred in 9.0% of EES patients and 13.7% of PES patients (relative risk [RR]: 0.66; 95% confidence interval [CI]: 0.50 to 0.86) driven by a lower rate of myocardial infarction (3.9% vs. 7.5%; RR: 0.52; 95% CI: 0.35 to 0.77) and target vessel revascularization (3.2% vs. 8.0%; RR: 0.41; 95% CI: 0.27 to 0.62), in parallel with a lower rate of definite or probable stent thrombosis (0.9% vs. 3.9%; RR: 0.23; 95% CI: 0.11 to 0.49). Differences significantly increased between 1-and 2-year follow-up for the primary composite endpoint (p = 0.04), target vessel revascularization (p = 0.02), and definite or probable stent thrombosis (p = 0.02). Conclusions The substantial clinical benefit of the EES over the PES with regard to measures of both safety and efficacy is maintained at 2 years in real-life practice with an increasing benefit in terms of safety and efficacy between 1 year and 2 years. Comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: a randomized open label trial: The COMPARE Trial [COMPARE 1]; NCT01016041) (J Am Coll Cardiol 2011; 58:11-8) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:11 / 18
页数:8
相关论文
共 13 条
[1]   Long-term follow-up of the randomised controlled trial to evaluate the safety and efficacy of the zotarolimus-eluting driver coronary stent in de novo native coronary artery lesions: five year outcomes in the ENDEAVOR II study [J].
Fajadet, Jean ;
Wijns, William ;
Laarman, Gert-Jan ;
Kuck, Karl-Heinz ;
Ormiston, John ;
Baldus, Stephan ;
Hauptmann, Karl E. ;
Suttorp, Maarten D. ;
Drzewiecki, Janusz ;
Pieper, Michael ;
Schultheiss, Heinz-Peter ;
Mauri, Laura .
EUROINTERVENTION, 2010, 6 (05) :562-567
[2]   Endothelial cell recovery between comparator polymer-based drug-eluting stents [J].
Joner, Michael ;
Nakazawa, Gaku ;
Finn, Aloke V. ;
Quee, Shawn Chin ;
Coleman, Leslie ;
Acampado, Eduardo ;
Wilson, Patricia S. ;
Skorija, Kristi ;
Cheng, Qi ;
Xu, Xin ;
Gold, Herman K. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) :333-342
[3]   Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial [J].
Kedhi, Elvin ;
Joesoef, Kaiyum Sheik ;
McFadden, Eugene ;
Wassing, Jochem ;
van Mieghem, Carlos ;
Goedhart, Dick ;
Smits, Pieter Cornelis .
LANCET, 2010, 375 (9710) :201-209
[4]   Surface characterization and platelet adhesion studies on fluorocarbons prepared by plasma-induced graft polymerization [J].
Lin, JC ;
Tiong, SL ;
Chen, CY .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (07) :701-714
[5]   Novel Polymeric Coatings with the Potential to Control In-stent Restenosis - An In Vitro Study [J].
Nickson, C. M. ;
Doherty, P. J. ;
Williams, R. L. .
JOURNAL OF BIOMATERIALS APPLICATIONS, 2010, 24 (05) :437-452
[6]   Randomized comparison of everolimus- and paclitaxel-eluting stents: pooled analysis of the 2-year clinical follow-up from the SPIRIT II and III trials [J].
Onuma, Yoshinobu ;
Serruys, Patrick W. ;
Kukreja, Neville ;
Veldhof, Susan ;
Doostzadeh, Julie ;
Cao, Sherry ;
Stone, Gregg W. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1071-1078
[7]  
Serruys Patrick W, 2006, EuroIntervention, V2, P286
[8]   The Unrestricted Use of Sirolimus- and Paclitaxel-Eluting Stents Results in Better Clinical Outcomes During 6-Year Follow-Up Than Bare-Metal Stents An Analysis of the RESEARCH (Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital) and T-SEARCH (Taxus Stent Evaluated At Rotterdam Cardiology Hospital) Registries [J].
Simsek, Cihan ;
Magro, Michael ;
Boersma, Eric ;
Onuma, Yoshinobu ;
Nauta, Sjoerd T. ;
Gaspersz, Marcia P. ;
van der Giessen, Willem J. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (10) :1051-1058
[9]   Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease - A randomized trial [J].
Stone, Gregg W. ;
Midei, Mark ;
Newman, William ;
Sanz, Mark ;
Hermiller, James B. ;
Williams, Jerome ;
Farhat, Naim ;
Mahaffey, Kenneth W. ;
Cutlip, Donald E. ;
Fitzgerald, Peter J. ;
Sood, Poornima ;
Su, Xiaolu ;
Lansky, Alexandra J. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (16) :1903-1913
[10]   Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents [J].
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Ellis, Stephen G. ;
Schofer, Joachim ;
Dawkins, Keith D. ;
Morice, Marie-Claude ;
Colombo, Antonio ;
Schampaert, Erick ;
Grube, Eberhard ;
Kirtane, Ajay J. ;
Cutlip, Donald E. ;
Fahy, Martin ;
Pocock, Stuart J. ;
Mehran, Roxana ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :998-1008