Polymer microfluidic chip for online monitoring of microarray hybridizations

被引:59
作者
Noerholm, M
Bruus, H
Jakobsen, MH
Telleman, P
Ramsing, NB
机构
[1] Exiqon AS, DK-2950 Vedboek, Denmark
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, MIC, DK-2800 Lyngby, Denmark
关键词
D O I
10.1039/b311991b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A disposable single use polymer microfluidics chip has been developed and manufactured by micro injection molding. The chip has the same outer dimensions as a standard microscope slide (25 x 76 x 1.1 mm) and is designed to be compatible with existing microscope slide handling equipment like microarray scanners. The chip contains an inlet, a 10 muL hybridization chamber capable of holding a 1000 spot array, a waste chamber and a vent to allow air to escape when sample is injected. The hybridization chamber ensures highly homogeneous hybridization conditions across the microarray. We describe the use of this chip in a flexible setup with fluorescence based detection, temperature control and liquid handling by computer controlled syringe pumps. The chip and the setup presented in this article provide a powerful tool for highly parallel studies of kinetics and thermodynamics of duplex formation in DNA microarrays. The experimental setup presented in this article enables the on-chip microarray to be hybridized and monitored at several different stringency conditions during a single assay. The performance of the chip and the setup is demonstrated by on-line measurements of a hybridization of a DNA target solution to a microarray. A presented numerical model indicates that the hybridization process in microfluidic hybridization assays is diffusion limited, due to the low values of the diffusion coefficients D of the DNA and RNA molecules involved.
引用
收藏
页码:28 / 37
页数:10
相关论文
共 35 条
[1]  
ATKINS PW, 1990, PHYSICAL CHEM
[2]  
Bowtell D., 2003, DNA MICROARRAYS MOL
[3]   Quantitative 3-dimensional profiling of channel networks within transparent 'lab-on-a-chip' microreactors using a digital imaging method [J].
Broadwell, I ;
Fletcher, PDI ;
Haswell, SJ ;
McCreedy, T ;
Zhang, XL .
LAB ON A CHIP, 2001, 1 (01) :66-71
[4]  
BRUUS H, 2004, UNPUB DIFFUSION MICR
[5]  
BUR AJ, 2000, SOC PLAST ENG TECHN, V2, P348
[6]  
Chan CM, 1996, SURF SCI REP, V24, P3
[7]  
FIXE F, 2003, IN PRESS NUCL ACIDS
[8]   MULTIPLEXED BIOCHEMICAL ASSAYS WITH BIOLOGICAL CHIPS [J].
FODOR, SPA ;
RAVA, RP ;
HUANG, XHC ;
PEASE, AC ;
HOLMES, CP ;
ADAMS, CL .
NATURE, 1993, 364 (6437) :555-556
[9]   Surface modification of poly(methyl methacrylate) used in the fabrication of microanalytical devices [J].
Henry, AC ;
Tutt, TJ ;
Galloway, M ;
Davidson, YY ;
McWhorter, CS ;
Soper, SA ;
McCarley, RL .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5331-5337
[10]   Measurement of residual stresses in injection-molded polymer parts by time-resolved fluorescence [J].
Ikawa, T ;
Shiga, T ;
Okada, A .
JOURNAL OF APPLIED POLYMER SCIENCE, 2002, 83 (12) :2600-2603