Clinical presentation, investigation, and management of pulmonary vein stenosis complicating ablation for atrial fibrillation

被引:207
作者
Packer, DL [1 ]
Keelan, P [1 ]
Munger, TM [1 ]
Breen, JF [1 ]
Asirvatham, S [1 ]
Peterson, LA [1 ]
Monahan, KH [1 ]
Hauser, MF [1 ]
Chandrasekaran, K [1 ]
Sinak, LJ [1 ]
Holmes, DR [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Cardiac Electrophysiol Cardiol, Rochester, MN 55902 USA
关键词
fibrillation; atrial; ablation; catheter; pulmonary heart disease; stenosis;
D O I
10.1161/01.CIR.0000154541.58478.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Although segmental or circumferential ablation is effective in eliminating pulmonary vein ( PV) - mediated atrial fibrillation ( AF), this procedure may be complicated by the occurrence of PV stenosis. Methods and Results - To establish the clinical presentation, diagnostic manifestations, and interventional management of PV stenosis, 23 patients with stenosis of 34 veins complicating ablation of AF were evaluated. Each patient became symptomatic 103 +/- 100 days after undergoing ablation. In 8 veins, the ablation producing the PV stenosis was a repeated procedure for continued AF. Nineteen patients presented with dyspnea on exertion, 7 with dyspnea at rest, 9 with cough, and 6 with chest pain. On multirow spiral computed tomography examination, the narrowest lumen of the affected PVs measured 3 +/- 2 mm compared with 13 +/- 3 mm at baseline ( P less than or equal to 0.001). The relative perfusion of affected lung segments on isotope scans was reduced to 4 +/- 3% of total perfusion compared with 22 +/- 10% in unaffected segments. At percutaneous intervention, these veins showed 80 +/- 13% stenosis, with a mean gradient of 12 +/- 5 mm Hg. This was significantly reduced to a residual stenosis of 9 +/- 8% ( P less than or equal to 0.001) and a residual gradient of 3 +/- 4 mmHg ( P less than or equal to 0.001). Twenty veins were treated with balloon dilatation alone, whereas 14 veins were stented with standard 10- mm- diameter bare- metal stents. Although the symptomatic response was nearly immediate and impressive, 14 patients developed in- stent or in- segment restenosis, requiring repeated interventions in 13. Conclusions - Percutaneous intervention produces rapid and dramatic symptom relief in patients with highly symptomatic PV stenosis after radiofrequency ablation for AF. Nevertheless, alternative treatment methods will be required to decrease recurrent in- stent or in- segment restenosis.
引用
收藏
页码:546 / 554
页数:9
相关论文
共 37 条
[1]  
Allesie MA, 1990, CARDIAC ELECTROPHYSI, P548
[2]  
ASIRVATHAM S, 2000, PACING CLIN ELECTROP, V23, P649
[3]  
Caldarone CA, 1998, ANN THORAC SURG, V66, P1514, DOI 10.1016/S0003-4975(98)00952-7
[4]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[5]  
ERNST S, 2002, PACING CLIN ELECTROP, V25, P638
[6]   Clinical outcome after radiofrequency catheter ablation of focal atrial fibrillation triggers [J].
Gerstenfeld, EP ;
Guerra, P ;
Sparks, PB ;
Hattori, K ;
Lesh, MD .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) :900-908
[7]   Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Garrigue, S ;
Takahashi, A ;
Lavergne, T ;
Hocini, M ;
Peng, JT ;
Roudaut, R ;
Clementy, J .
CIRCULATION, 2000, 101 (12) :1409-1417
[8]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[9]   RESPONSES OF SYSTEMIC AND PULMONARY VEINS TO THE PRESENCE OF AN INTRAVASCULAR STENT IN A SWINE MODEL [J].
HOSKING, M ;
REDMOND, M ;
ALLEN, L ;
BROECKER, L ;
KEANEY, M ;
LEBEAU, J ;
WALLEY, V .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (01) :90-96
[10]   A focal source of atrial fibrillation treated by discrete radiofrequency ablation [J].
Jais, P ;
Haissaguerre, M ;
Shah, DC ;
Chouairi, S ;
Gencel, L ;
Hocini, M ;
Clementy, J .
CIRCULATION, 1997, 95 (03) :572-576