Sensitive skin and stratum corneum reactivity to household cleaning products

被引:27
作者
Goffin, V [1 ]
PierardFranchimont, C [1 ]
Pierard, GE [1 ]
机构
[1] UNIV LIEGE,DEPT DERMATOPATHOL,LAB DERMOMETROL,B-4000 LIEGE,BELGIUM
关键词
corneosurfametry; fabrics; irritation; sensitive skin; surfactant; stratum corneum; bioengineering methods;
D O I
10.1111/j.1600-0536.1996.tb02134.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Products intended for individuals with sensitive skin are being increasingly developed by formulators of household cleaning products. However, there is currently no consensus about the definition and recognition of the biological basis of sensitive skin. We sought to determine the relation between the nature of environmental threat perceived as aggressive by panelists, and the stratum corneum reactivity to household cleaning products as measured by the corneosurfametry test. Results indicate substantial differences in irritancy potential between proprietary products. Corneosurfametry data show significant differences in stratum corneum reactivity between, on the one hand, individuals with either non-sensitive skin or skin sensitive to climate/fabrics, and, on the other hand, individuals with detergent-sensitive skin. It is concluded that sensitive skin is not one single condition. Sound information in rating detergent-sensitive skin may be gained by corneosurfametry. (C) Munksgaard, 1996.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 15 条
[1]   SEASONAL-VARIATION OF SKIN RESISTANCE TO IRRITANTS [J].
AGNER, T ;
SERUP, J .
BRITISH JOURNAL OF DERMATOLOGY, 1989, 121 (03) :323-328
[2]   ADVERSE-EFFECTS OF COSMETICS AND TOILETRIES - A RETROSPECTIVE STUDY IN THE GENERAL-POPULATION [J].
DEGROOT, AC ;
NATER, JP ;
VANDERLENDE, R ;
RIJCKEN, B .
INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 1987, 9 (06) :255-259
[3]   COMPARISON OF IN-VITRO PREDICTIVE TESTS FOR IRRITATION INDUCED BY ANIONIC SURFACTANTS [J].
GOFFIN, V ;
PAYE, M ;
PIERARD, GE .
CONTACT DERMATITIS, 1995, 33 (01) :38-41
[4]  
KLEIN G, 1992, BRIT J DERMATOL, V127, P131
[5]   THE INVISIBLE DERMATOSES [J].
KLIGMAN, AM .
ARCHIVES OF DERMATOLOGY, 1991, 127 (09) :1375-1382
[6]   THOUGHTS ON IRRITANT CONTACT-DERMATITIS [J].
MALTEN, KE .
CONTACT DERMATITIS, 1981, 7 (05) :238-247
[7]   DANSYL CHLORIDE LABELING OF STRATUM-CORNEUM - ITS RAPID EXTRACTION FROM SKIN CAN PREDICT SKIN IRRITATION DUE TO SURFACTANTS AND CLEANSING PRODUCTS [J].
PAYE, M ;
SIMION, FA ;
PIERARD, GE .
CONTACT DERMATITIS, 1994, 30 (02) :91-96
[8]  
Paye M, 1995, Skin Res Technol, V1, P30, DOI 10.1111/j.1600-0846.1995.tb00011.x
[9]   SURFACTANT-INDUCED DERMATITIS - COMPARISON OF CORNEOSURFAMETRY WITH PREDICTIVE TESTING ON HUMAN AND RECONSTRUCTED SKIN [J].
PIERARD, GE ;
GOFFIN, V ;
HERMANNSLE, T ;
ARRESE, JE ;
PIERARDFRANCHIMONT, C .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1995, 33 (03) :462-469
[10]   CORNEOSURFAMETRY - A PREDICTIVE ASSESSMENT OF THE INTERACTION OF PERSONAL-CAVE CLEANSING PRODUCTS WITH HUMAN STRATUM-CORNEUM [J].
PIERARD, GE ;
GOFFIN, V ;
PIERARDFRANCHIMONT, C .
DERMATOLOGY, 1994, 189 (02) :152-156