A real-time audit of radiation therapy in a Regional Cancer Center

被引:65
作者
Brundage, MD
Dixon, PF
Mackillop, WJ
Shelley, WE
Hayter, CRR
Paszat, LF
Youssef, YM
Robins, JM
McNamee, A
Cornell, A
机构
[1] Kingston Gen Hosp, Radiat Oncol Res Unit, Kingston, ON K7L 2V7, Canada
[2] Kingston Gen Hosp, Kingston Reg Canc Ctr, Kingston, ON K7L 2V7, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 01期
关键词
quality assurance; outcome and process assessment;
D O I
10.1016/S0360-3016(98)00368-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report the development, structure, and implementation of a real-time clinical radiotherapy audit of the practice of radiation oncology in a regional cancer center. Methods and Materials: Radiotherapy treatment plans were audited by a real-time peer-review process over an 8-year period (1989-1996). The overall goal of the audit was to establish a process for quality assurance (QA) of radiotherapy planning and prescription for individual patients. A parallel process was developed to audit the implementation of intervention-specific radiotherapy treatment policies. Results: A total of 3052 treatment plans were audited. Of these, 124 (4.1%) were not approved by the audit due to apparent errors in radiation planning. The majority of the nonapproved plans (79%) were modified prior to initiating treatment; the audit provided important clinical feedback about individual patient care in these instances, Most of the remaining nonapproved plans were deviations from normal practice due to patient-specific considerations. A further 110 (3.6% of all audited plans) were not approved by the audit due to deviations from radiotherapy treatment policy. A minority of these plans (22%) were modified prior to initiating treatment and the remainder provided important feedback for continuous quality improvement of treatment policies. Conclusion: A real-time audit of radiotherapy practice in a regional cancer center setting proved feasible and provided important direct and indirect patient benefits. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:115 / 124
页数:10
相关论文
共 41 条
[1]  
*AG HLTH CAR POL R, 1990, CLIN GUID DEV
[2]  
[Anonymous], 1993, 50 ICRU
[3]  
BASINSKI ASH, 1992, CAN MED ASSOC J, V146, P833
[4]   QUALITY ASSURANCE IN RADIATION-THERAPY - SYSTEMATIC EVALUATION OF ERRORS DURING THE TREATMENT EXECUTION [J].
BLANCO, S ;
LOPEZBOTE, MA ;
DESCO, M .
RADIOTHERAPY AND ONCOLOGY, 1987, 8 (03) :253-261
[5]  
BUSH R S, 1984, International Journal of Radiation Oncology, Biology, Physics, V10, P19
[6]  
CHAFFEY J T, 1984, International Journal of Radiation Oncology, Biology, Physics, V10, P15
[7]   A QUALITY ASSURANCE PROGRAM FOR MONITOR UNIT CALCULATORS [J].
DAHL, RA ;
MCCULLOUGH, EC ;
MELLENBERG, DE .
MEDICAL PHYSICS, 1990, 17 (01) :103-105
[8]  
de Almeida C E, 1984, Int J Radiat Oncol Biol Phys, V10 Suppl 1, P99, DOI 10.1016/0360-3016(84)90456-5
[9]  
DISCHE S, 1984, International Journal of Radiation Oncology, Biology, Physics, V10, P55
[10]   QUALITY-CONTROL OF RADIOTHERAPY CENTERS IN EUROPE - BEAM CALIBRATION [J].
DUTREIX, A ;
DERREUMAUX, S ;
CHAVAUDRA, J ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :256-264