Perioperative practical experiences in using a level 2 portable polysomnography

被引:26
作者
Chung, Frances [1 ]
Liao, Pu
Sun, Yuming
Amirshahi, Babak
Fazel, Hoda
Shapiro, Colin M. [2 ]
Elsaid, Hisham
机构
[1] Univ Toronto, Univ Hlth Network, Toronto Western Hosp, Dept Anesthesia, Toronto, ON M5T 2S8, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto Western Hosp, Dept Psychiat, Toronto, ON M5T 2S8, Canada
关键词
Polysomnography; Perioperative; Obstructive sleep apnea; Sleep architecture; OBSTRUCTIVE SLEEP-APNEA; POSTOPERATIVE COMPLICATIONS; HEART-FAILURE; OLDER-ADULTS; DIAGNOSIS; VALIDATION; SYSTEM; HOME; ASSOCIATION; PREVALENCE;
D O I
10.1007/s11325-010-0340-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
The objective of the study is to test the hypothesis that a level 2 portable sleep device (Embletta X100) is a reliable alternative for standard PSG in surgical patients. After hospital ethics approvals, preoperative patients over 18 years old were recruited. The patients for validation underwent standard PSG and Embletta X100 simultaneously in a sleep laboratory before surgery. The other patients received sleep studies with Embletta X100 perioperatively. The correlation analysis and paired Student t test between variables from Embletta and from standard PSG were used to evaluate the accuracy of Embletta. The quality of PSG recordings with Embletta was summarized. Twenty-one patients completed sleep study on both systems; ten females and ten males, age was 54 +/- 11 and BMI was 36 +/- 9. There was a significant correlation between the majority of parameters from standard PSG and Embeltta X100 with manual scoring. The inter-rater agreement was substantial to perfect at different AHI cutoffs with a Kappa coefficient of 0.69 to 1. A significant correlation between standard PSG and Embletta X100 with automatic scoring was found only in AHI and a few other parameters. In 385 patients, 1,002 perioperative PSG recordings were carried out with Embletta. Of them, 889(88.7%) were technically good and 90(9%) technically acceptable. Only 23 (2.3%) PSG recordings failed. Embletta X100, installed by a well-trained sleep technician, is a good alternative when standard PSG was not available or impractical. Manual scoring by a certified PSG technologist is the key for reliable results.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 43 条
[1]
Evaluation of a home respiratory polygraphy system in the diagnosis of the obstructive sleep apnoea syndrome [J].
Abdelghani, A. ;
Roisman, G. ;
Escourrou, P. .
REVUE DES MALADIES RESPIRATOIRES, 2007, 24 (03) :331-338
[2]
Amer Soc Anesthesiologists, 2006, ANESTHESIOLOGY, V104, P1081
[3]
Ayappa I, 2008, J CLIN SLEEP MED, V4, P26
[4]
Assessment of a wrist-worn device in the detection of obstructive sleep apnea [J].
Ayas, NT ;
Pittman, S ;
MacDonald, M ;
White, DP .
SLEEP MEDICINE, 2003, 4 (05) :435-442
[5]
Effects of age on sleep apnea in men I. Prevalence and severity [J].
Bixler, EO ;
Vgontzas, AN ;
Ten Have, T ;
Tyson, K ;
Kales, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (01) :144-148
[6]
Prevalence of sleep-disordered breathing in women - Effects of gender [J].
Bixler, EO ;
Vgontzas, AN ;
Lin, HM ;
Ten Have, T ;
Rein, J ;
Vela-Bueno, A ;
Kales, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (03) :608-613
[7]
EPIDEMIOLOGY OF OBSTRUCTIVE SLEEP-APNEA [J].
BRESNITZ, EA ;
GOLDBERG, R ;
KOSINSKI, RM .
EPIDEMIOLOGIC REVIEWS, 1994, 16 (02) :210-227
[8]
Bridevaux PO, 2007, SWISS MED WKLY, V137, P602
[9]
Chesson AL, 1997, SLEEP, V20, P406
[10]
STOP questionnaire - A tool to screen patients for obstructive sleep apnea [J].
Chung, Frances ;
Yegneswaran, Balaji ;
Liao, Pu ;
Chung, Sharon A. ;
Vairavanathan, Santhira ;
Islam, Sazzadul ;
Khajehdehi, Ali ;
Shapiro, Colin M. .
ANESTHESIOLOGY, 2008, 108 (05) :812-821