Hydrodynamic guiding for addressing subsets of immobilized cells and molecules in microfluidic systems -: art. no. 10

被引:18
作者
Brevig, T
Krühne, U
Kahn, RA
Ahl, T
Beyer, M
Pedersen, LH
机构
[1] Inst Biotechnol, Dept Mol Characterizat, DK-2970 Horsholm, Denmark
[2] CelTor Biosyst Inc, Windamere Venture Partners LLC, San Diego, CA 92130 USA
关键词
D O I
10.1186/1472-6750-3-10
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: The interest in microfluidics and surface patterning is increasing as the use of these technologies in diverse biomedical applications is substantiated. Controlled molecular and cellular surface patterning is a costly and time-consuming process. Methods for keeping multiple separate experimental conditions on a patterned area are, therefore, needed to amplify the amount of biological information that can be retrieved from a patterned surface area. We describe, in three examples of biomedical applications, how this can be achieved in an open microfluidic system, by hydrodynamically guiding sample fluid over biological molecules and living cells immobilized on a surface. Results: A microfluidic format of a standard assay for cell-membrane integrity showed a fast and dose-dependent toxicity of saponin on mammalian cells. A model of the interactions of human mononuclear leukocytes and endothelial cells was established. By contrast to static adhesion assays, cell-cell adhesion in this dynamic model depended on cytokine-mediated activation of both endothelial and blood cells. The microfluidic system allowed the use of unprocessed blood as sample material, and a specific and fast immunoassay for measuring the concentration of C-reactive protein in whole blood was demonstrated. Conclusion: The use of hydrodynamic guiding made multiple and dynamic experimental conditions on a small surface area possible. The ability to change the direction of flow and produce two-dimensional grids can increase the number of reactions per surface area even further. The described microfluidic system is widely applicable, and can take advantage of surfaces produced by current and future techniques for patterning in the micro- and nanometer scale.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Physics and applications of microfluidics in biology [J].
Beebe, DJ ;
Mensing, GA ;
Walker, GM .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 :261-286
[2]   Biotechnology at low Reynolds numbers [J].
Brody, JP ;
Yager, P ;
Goldstein, RE ;
Austin, RH .
BIOPHYSICAL JOURNAL, 1996, 71 (06) :3430-3441
[3]  
Burghardt Robert C., 1994, P1231
[4]  
CARLOS T, 1991, BLOOD, V77, P2266
[5]   MEMBRANE-PROTEINS INVOLVED IN PHAGOCYTE ADHERENCE TO ENDOTHELIUM [J].
CARLOS, TM ;
HARLAN, JM .
IMMUNOLOGICAL REVIEWS, 1990, 114 :5-28
[6]   Patterned deposition of cells and proteins onto surfaces by using three-dimensional microfluidic systems [J].
Chiu, DT ;
Jeon, NL ;
Huang, S ;
Kane, RS ;
Wargo, CJ ;
Choi, IS ;
Ingber, DE ;
Whitesides, GM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (06) :2408-2413
[7]   A microfabricated device for sizing and sorting DNA molecules [J].
Chou, HP ;
Spence, C ;
Scherer, A ;
Quake, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (01) :11-13
[8]   A microchip-based multianalyte assay system for the assessment of cardiac risk [J].
Christodoulides, N ;
Tran, M ;
Floriano, PN ;
Rodriguez, M ;
Goodey, A ;
Ali, M ;
Neikirk, D ;
McDevitt, JT .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3030-3036
[9]   FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION [J].
DAVIES, PF .
PHYSIOLOGICAL REVIEWS, 1995, 75 (03) :519-560
[10]   C-reactive protein and cardiovascular disease: a review of risk prediction and interventions [J].
de Ferranti, S ;
Rifai, N .
CLINICA CHIMICA ACTA, 2002, 317 (1-2) :1-15