Comparative study of BacT/Alert FAN bottles and standard BacT/Alert bottles

被引:12
作者
Gibb, AP [1 ]
Hill, B [1 ]
Chorel, B [1 ]
机构
[1] Foothills Hosp, Dept Microbiol & Infect Dis, Calgary, AB T2N 2T9, Canada
关键词
D O I
10.1016/S0732-8893(98)00094-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
A total of 5,230 paired blood cultures were sstudied. One sample was divided between aerobic and anaerobic BacT/Alert standard bottles, and the other divided between aerobic and anaerobic BacT/Alert FAN bottles. There mere 44 occasions where Staphylococcus aureus was I recovered only from the FAN bottles, compared to six where only the standard: bottles were positive (p < 0.001), and 21 occasions where Escherichia coli was isolated only from FAN bottles, compared to eight occasion where only the standard bottles were positive for this organism (p < 0.05). In 21 of 28 cases reviewed where S. aureus was isolated from FAN bottles only the patient had been receiving anti-staphylococcal antibiotics. However, only 2 of 30 cases where Gram-negative bacilli were isolated from FAN bottles had documented recent appropriate antibiotic therapy. Patients iii whom FAN bottles ave more likely to recover organisms cannot be selected on the basis of documented antibotic treatment. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 10 条
[1]  
BRYANT DH, 1994, 94 GEN M AM SOC MICR
[2]  
DOERN GV, 1994, BLOOD CULTURES, P133
[3]  
Gibb AP, 1997, ARCH PATHOL LAB MED, V121, P503
[4]   STATISTICAL-METHODS IN MICROBIOLOGY [J].
ILSTRUP, DM .
CLINICAL MICROBIOLOGY REVIEWS, 1990, 3 (03) :219-226
[5]   Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles [J].
McDonald, LC ;
Fune, J ;
Gaido, LB ;
Weinstein, MP ;
Reimer, LG ;
Flynn, TM ;
Wilson, ML ;
Mirrett, S ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) :2180-2184
[6]   Update on detection of bacteremia and fungemia [J].
Reimer, LG ;
Wilson, ML ;
Weinstein, MP .
CLINICAL MICROBIOLOGY REVIEWS, 1997, 10 (03) :444-&
[7]  
SKULNICK M, 1996, 96 GEN M AM SOC MICR
[8]   CONTROLLED EVALUATION OF BACT ALERT STANDARD AEROBIC AND FAN AEROBIC BLOOD CULTURE BOTTLES FOR DETECTION OF BACTEREMIA AND FUNGEMIA [J].
WEINSTEIN, MP ;
MIRRETT, S ;
REIMER, LG ;
WILSON, ML ;
SMITHELEKES, S ;
CHUARD, CR ;
JOHO, KL ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) :978-981
[9]   Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures [J].
WelbySellenriek, PL ;
Keller, DS ;
Ferrett, RJ ;
Storch, GA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (05) :1166-1171
[10]   CONTROLLED EVALUATION OF BACT ALERT STANDARD ANAEROBIC AND FAN ANAEROBIC BLOOD CULTURE BOTTLES FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA [J].
WILSON, ML ;
WEINSTEIN, MP ;
MIRRETT, S ;
REIMER, LG ;
FELDMAN, RJ ;
CHUARD, CR ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (09) :2265-2270