Ne novo sequencing of tryptic peptides sulfonated by 4-sulfophenyl isothiocyanate for unambiguous protein identification using post-source decay matrix-assisted laser desorption/ionization mass spectrometry

被引:53
作者
Chen, P [1 ]
Nie, S [1 ]
Mi, W [1 ]
Wang, XC [1 ]
Liang, SP [1 ]
机构
[1] Hunan Normal Univ, Coll Life Sci, Changsha 410081, Peoples R China
关键词
D O I
10.1002/rcm.1280
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method of solid-phase derivatization and sequencing of tryptic peptides has been developed for rapid and unambiguous identification of spots on two-dimensional gels using post-source decay (PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The proteolytic digests of proteins are chemically modified by 4-sulfophenyl isothiocyanate. The derivatization reaction introduces a negative sulfonic acid group at the N-terminus of a peptide, which can increase the efficiency of PSD fragmentation and enable the selective detection of only a single series of fragment ions (y-ions). This chemically assisted method avoids the limitation of high background normally observed in MALDI-PSD spectra, and makes the spectra easier to interpret and facilitates de novo sequencing of internal fragment. The modification reaction is conducted in C-18 muZipTips to decrease the background and to enhance the signal/noise. Derivatization procedures were optimized for MALDI-PSD to increase the structural information and to obtain a complete peptide sequence even in critical cases. The MALDI-PSD mass spectra of two model peptides and their sulfonated derivatives are compared. For some proteins unambiguous identification could be achieved by MALDI-PSD sequencing of derivatized peptides obtained from in-gel digests of phosphorylase B and proteins of hepatic satellite cells (HSC). Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 30 条
[1]  
Beardsley RL, 2000, RAPID COMMUN MASS SP, V14, P2147, DOI 10.1002/1097-0231(20001215)14:23<2147::AID-RCM145>3.0.CO
[2]  
2-M
[3]   C-terminal sequence analysis of peptides and proteins using carboxypeptidases and mass spectrometry after derivatization of Lys and Cys residues [J].
Bonetto, V ;
Bergman, AC ;
Jornvall, H ;
Sillard, R .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1315-1319
[4]   Influence of peptide composition, gas-phase basicity, and chemical modification on fragmentation efficiency: Evidence for the mobile proton model [J].
Dongre, AR ;
Jones, JL ;
Somogyi, A ;
Wysocki, VH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (35) :8365-8374
[5]   Routine identification of proteins from sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gels or polyvinyl difluoride membranes using matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) [J].
Fernandez, J ;
Gharahdaghi, F ;
Mische, SM .
ELECTROPHORESIS, 1998, 19 (06) :1036-1045
[6]  
Gevaert K, 2001, ELECTROPHORESIS, V22, P1645, DOI 10.1002/1522-2683(200105)22:9<1645::AID-ELPS1645>3.0.CO
[7]  
2-Z
[8]  
Gharahdaghi F, 1999, ELECTROPHORESIS, V20, P601, DOI 10.1002/(SICI)1522-2683(19990301)20:3<601::AID-ELPS601>3.0.CO
[9]  
2-6
[10]   Increased sensitivity of tryptic peptide detection by MALDI-TOF mass spectrometry is achieved by conversion of lysine to homoarginine [J].
Hale, JE ;
Butler, JP ;
Knierman, MD ;
Becker, GW .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :110-117