A high-speed data acquisition system for ECT based on the differential sampling method

被引:42
作者
Wang, BL [1 ]
Ji, HF [1 ]
Huang, ZY [1 ]
Li, HQ [1 ]
机构
[1] Zhejiang Univ, Dept Control Sci & Engn, Inst Instrumentat, Hangzhou 310027, Peoples R China
基金
国家科技攻关计划;
关键词
capacitance measurement; tomography;
D O I
10.1109/JSEN.2004.842627
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new capacitance measuring circuit based on differential sampling methods for electrical capacitance tomography has been developed. The measured capacitance is only charged and discharged once and no noise is created by the measurement principle. A capacitance measurement system for 12 electrodes is constructed based on the new measurement circuit. Test results show the data acquisition time for 66 capacitances (for reconstructing one image) is less than 1.25 ms.
引用
收藏
页码:308 / 312
页数:5
相关论文
共 4 条
[1]   DESIGN OF SENSOR ELECTRONICS FOR ELECTRICAL CAPACITANCE TOMOGRAPHY [J].
HUANG, SM ;
XIE, CG ;
THORN, R ;
SNOWDEN, D ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :83-88
[2]   Application of electrical capacitance tomography to the void fraction measurement of two-phase flow [J].
Huang, ZY ;
Wang, BL ;
Li, HQ .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (01) :7-12
[3]   ELECTRICAL CAPACITANCE TOMOGRAPHY FOR FLOW IMAGING - SYSTEM MODEL FOR DEVELOPMENT OF IMAGE-RECONSTRUCTION ALGORITHMS AND DESIGN OF PRIMARY SENSORS [J].
XIE, CG ;
HUANG, SM ;
HOYLE, BS ;
THORN, R ;
LENN, C ;
SNOWDEN, D ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :89-98
[4]   HIGH-FREQUENCY AND HIGH-RESOLUTION CAPACITANCE MEASURING CIRCUIT FOR PROCESS TOMOGRAPHY [J].
YANG, WQ ;
STOTT, AL ;
BECK, MS .
IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 1994, 141 (03) :215-219