Suprasternal Doppler ultrasound for assessment of stroke distance

被引:12
作者
Childs, C
Goldring, S
Tann, W
Hillier, VF
机构
[1] Booth Hall Childrens Hosp, Reg Paediat Burns Unit, Manchester M9 7AA, Lancs, England
[2] Univ Manchester, MRC, Trauma Grp, Manchester, Lancs, England
[3] Univ Manchester, Dept Med Biophys, Manchester, Lancs, England
关键词
Doppler ultrasound; stroke distance; measurement error;
D O I
10.1136/adc.79.3.251
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
An assessment of a non-invasive technique for measurement of stroke distance was made using a portable Doppler ultrasound machine. The aim was to determine the measurement error of repeated stroke distance measurements (within-observer variability) and to assess measurement agreement between two operators (between-observer variability), The measurement error (within-observer variability) for both operators was similar at approximately 2 cm. :However, the measurements of the two operators (between-observer variability) did not agree well. Using the mean (SD) of three readings by each operator, the mean difference between the operators was -0.21 cm (1.96) giving a 95% confidence interval for the differences of -4.0 to +3.6 cm. There were significant positive and negative correlations between stroke distance and a variety of variables (age, height, weight, heart rate), but the relations were weak. The results indicate that the Doppler ultrasound technique for measurement of stroke distance would best be used to study trend changes in an individual patient, or subject, by a single operator.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 12 条
[1]   Measurement error [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 312 (7047) :1654-1654
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
DEMLING RH, 1989, INFECTION SEPSIS BUR
[4]   RELATIONSHIP BETWEEN AGE, BODY SIZE, GENDER, AND BLOOD-PRESSURE AND DOPPLER FLOW MEASUREMENTS IN THE AORTA AND PULMONARY-ARTERY [J].
GARDIN, JM ;
DAVIDSON, DM ;
ROHAN, MK ;
BUTMAN, S ;
KNOLL, M ;
GARCIA, R ;
DUBRIA, S ;
GARDIN, SK ;
HENRY, WL .
AMERICAN HEART JOURNAL, 1987, 113 (01) :101-109
[5]  
HAITES NE, 1984, LANCET, V2, P1025
[6]  
HAITES NE, 1985, BRIT HEART J, V53, P123
[7]  
HANSEN G, 1994, IEEE SOFTWARE, V11, P5
[8]  
MALAGON I, 1996, MED SCI MONIT, V2, P514
[9]   AORTIC BLOOD VELOCITY-MEASUREMENT IN HEALTHY-ADULTS USING A SIMPLE ULTRASOUND TECHNIQUE [J].
MOWAT, DHR ;
HAITES, NE ;
RAWLES, JM .
CARDIOVASCULAR RESEARCH, 1983, 17 (02) :75-80
[10]  
MUIR IFK, 1987, BURNS THEIR TREATMEN