Quality criteria for cardiac images in diagnostic and interventional cardiology

被引:11
作者
Bernardi, G
Padovani, R
Morocutti, G
Spedicato, L
Giannuleas, JD
Neofotistou, E
Manginas, A
Goicolea, J
McNeill, J
Vaño, E
Marzocchi, A
Tsapaki, V
Fioretti, PM
Malone, J
机构
[1] Azienda Ospedaliera S Maria della Misericordia, Unita Operativa Cardiol, I-33100 Udine, Italy
[2] Azienda Ospedaliera S Maria della Misericordia, Unita Fis Sanitaria, I-33100 Udine, Italy
[3] Univ Complutense Madrid, Fac Med, Catedra Fis Med, Madrid, Spain
[4] Athens Gen Reg Hosp, Dept Cardiol, Athens, Greece
[5] Athens Gen Reg Hosp, Dept Phys, Athens, Greece
[6] Onassis Cardiac Surg Ctr, Dept Cardiol, Athens, Greece
[7] Hosp Meixoeiro, Dept Cardiol, Vigo, Spain
[8] Royal Brompton Hosp, Dept Cardiol, London SW3 6LY, England
[9] Policlin S Orsola, Div Cardiol, Dept Cardiovasc, Bologna, Italy
[10] St James Hosp, Dept Med Phys & Bioengn, Dublin 8, Ireland
[11] Trinity Coll, Dublin, Ireland
关键词
D O I
10.1259/bjr.74.885.740852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of cardiac imaging plays a pivotal role in clinical decision-making and depends mainly on the technical performance of the imaging system and on angiographic technique. The Italian Society of Invasive Cardiology and The Italian Society of Physics in Medicine have set quality criteria giving precise guidelines regarding how an angiogram should appear provided that good equipment and correct angiographic technique are used. The criteria have been reviewed by the European Concerted Action DIMOND Cardiology group and are reported here to provide a reference standard for images for the most common procedures in daily practice.
引用
收藏
页码:852 / 855
页数:4
相关论文
共 15 条
[1]   A method based on DIMOND quality criteria to evaluate imaging in diagnostic and interventional cardiology [J].
Bernardi, G ;
Padovani, R ;
Morocutti, G ;
Spedicato, L ;
Giannuleas, JD ;
Neofotistou, E ;
Maginas, A ;
Goicolea, JC ;
McNeill, J ;
Vañó, E .
RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) :167-172
[2]   Quality criteria implementation for brain computed tomography examinations [J].
Calzado, A ;
Rodríguez, R ;
Muñoz, A .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :65-68
[3]   GUIDELINES FOR TRAINING, CREDENTIALING, AND MAINTENANCE OF COMPETENCE FOR THE PERFORMANCE OF CORONARY ANGIOPLASTY - A REPORT FROM THE INTERVENTIONAL CARDIOLOGY COMMITTEE AND THE TRAINING-PROGRAM STANDARDS COMMITTEE OF THE SOCIETY-FOR-CARDIAC-ANGIOGRAPHY-AND-INTERVENTIONS [J].
COWLEY, MJ ;
FAXON, DP ;
HOLMES, DR .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (01) :1-4
[4]  
European Commission, 1996, 16260 EUR
[5]  
European Commission, 1996, 16261 EUR COMM
[6]  
European guidelines on quality criteria for computed tomography, 1999, 16262 EUR
[7]  
*GRUPP STUD, 1997, EMODINAMICA S, V10, P9
[8]   GUIDELINES FOR CONTINUOUS QUALITY IMPROVEMENT IN THE CARDIAC-CATHETERIZATION LABORATORY [J].
HEUPLER, FA ;
ALHANI, AJ ;
DEAR, WE .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (03) :191-200
[9]  
MACCIA C, 1995, RADIAT PROT DOSIM, V57, P111
[10]   Measurement of image quality in diagnostic radiology [J].
Martin, CJ ;
Sharp, PF ;
Sutton, DG .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :21-38