A tongs-like intraoperative γ-probe for specific applications in radioguided oncological surgery

被引:3
作者
Dusi, W
Angelotti, P
Auricchio, N
Bollini, D
Donati, A
Landini, G
Moroni, C
机构
[1] Ist TESRE, CNR, I-40129 Bologna, Italy
[2] Ist Nazl Fis Nucl, Sez Bologna, I-40127 Bologna, Italy
[3] Univ Parma, Dipartimento Fis, I-43100 Parma, Italy
[4] Univ Bologna, Dipartimento Fis, I-40126 Bologna, Italy
关键词
intraoperative gamma-probe; surgical probe; X- and gamma-ray detectors;
D O I
10.1016/S0168-9002(00)00523-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new type of hand-held non-imaging intraoperative gamma -probe, characterized by two detection systems each based on a square array 1 cm(2) in size of CdTe semiconductor crystals, is presented. The detectors are mounted at the end of two long arms of a tongs-like mechanical device, with the gamma -radiation entrance windows face to face. The tissues and/or organs to be inspected are placed between the detectors whose distance can be adjusted from 0.8 to about 3 cm. Due to its configuration, the tongs-like gamma -probe has an acceptance solid angle nearly two times larger than conventional intraoperative gamma -probes; furthermore, by shielding conveniently the back and the lateral sides of both detection systems, the local background can be meaningfully reduced so that an important increasing in signal-to-background ratio, therefore in sensitivity, is achievable, The scanning of the intestinal or colorectal walls, as well as other anatomic districts which can be sandwiched between the detectors, could be, for example, some specific surgical application for the tongs-like gamma -probe in order to detect intramural neoplastic lesion previously radiolabeled with specific markers. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 13 条
[1]   GAMMA-PROBE-GUIDED LYMPH-NODE LOCALIZATION IN MALIGNANT-MELANOMA [J].
ALEX, JC ;
WEAVER, DL ;
FAIRBANK, JT ;
RANKIN, BS ;
KRAG, DN .
SURGICAL ONCOLOGY-OXFORD, 1993, 2 (05) :303-308
[2]   Sentinel node biopsy: a revolution in the surgical management of breast cancer? [J].
Beechey-Newman, N .
CANCER TREATMENT REVIEWS, 1998, 24 (03) :185-203
[3]  
Benevento A, 1998, SEMIN SURG ONCOL, V15, P239, DOI 10.1002/(SICI)1098-2388(199812)15:4<239::AID-SSU11>3.0.CO
[4]  
2-4
[5]   A method to evaluate intra-operative gamma probes for sentinel lymph node localisation [J].
Britten, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (02) :76-83
[6]  
De Cicco C, 1998, SEMIN SURG ONCOL, V15, P268, DOI 10.1002/(SICI)1098-2388(199812)15:4<268::AID-SSU16>3.0.CO
[7]  
2-I
[8]  
JOSEPH E, 1999, CANCER J SCI AM, V3, P341
[9]   Radioimmunoguided surgery for colorectal cancer [J].
Manayan, RC ;
Hart, MJ ;
Friend, WG .
AMERICAN JOURNAL OF SURGERY, 1997, 173 (05) :386-389
[10]  
PAGANELLI G, 1994, J NUCL MED, V35, P1970