Solid-phase extraction with C30 bonded silica for analysis of polycyclic aromatic hydrocarbons in airborne particulate matters by gas chromatography-mass spectrometry

被引:64
作者
Li, Ke
Li, Haifang
Liu, Libin
Hashi, Yuki
Maeda, Tsuneaki
Lin, Jin-Ming [1 ]
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] Chinese Acad Sci, Res Ctr Eco Environm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[3] Natl Inst Adv Ind Sci & Technol, Div Analyt Chem, Tsukuba, Ibaraki 3058565, Japan
基金
中国国家自然科学基金;
关键词
triacontyl bonded silica; polycyclic aromatic hydrocarbons; airborne particulate matters; solid-phase extraction; gas chromatography-mass spectrometry;
D O I
10.1016/j.chroma.2007.03.129
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid-phase extraction (SPE) method using triacontyl bonded silica (C-30) as sorbent was developed for the determination of 16 US.Environmental Protection Agency polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matters quantitatively by gas chromatography-mass spectrometry (GC-MS). Optimization experiments were conducted using spiked standard aqueous solution of PAHs and real airborne particulates samples aiming to obtain highest SPE recoveries and extraction efficiency. Factors were studied in SPE procedures including the concentration of organic modifier, flow rate of sample loading and elution solvents. The ultrasonication time and solvents were also investigated. Recoveries were in the range of 68-107% for standard PAHs aqueous solution and 61-116% for real spiked sample. Limits of detection (LODs) and limits of quantification (LOQs) with standard solution were in the range of 0.0070-0.21 mu g L-1 and 0.022-0.67 mu g L-1, respectively. The optimized method was successfully applied to the determination of 16 PAHs in real airborne particulate matters. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 33 条
[1]  
AKISER J, 2005, SCIENCE, V307, P1858
[2]   Comparison of different drying, extraction and detection techniques for the determination of priority polycyclic aromatic hydrocarbons in background contaminated soil samples [J].
Berset, JD ;
Ejem, M ;
Holzer, R ;
Lischer, P .
ANALYTICA CHIMICA ACTA, 1999, 383 (03) :263-275
[3]   Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant [J].
Busetti, F ;
Heitz, A ;
Cuomo, M ;
Badoer, S ;
Traverso, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :104-115
[4]   Reversed-phase high-performance liquid chromatographic identification of lutein and zeaxanthin stereoisomers in bovine retina using a C30 bonded phase [J].
Dachtler, M ;
Kohler, K ;
Albert, K .
JOURNAL OF CHROMATOGRAPHY B, 1998, 720 (1-2) :211-216
[5]   Comparison of strategies for extraction of high molecular weight polycyclic aromatic hydrocarbons from drinking waters [J].
García-Falcón, MS ;
Pérez-Lamela, M ;
Simal-Gándara, J .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (23) :6897-6903
[6]  
*IARC, 1998, POL AR COMP 1, V32
[7]   ORGANICS IN WATER - SOLID-PHASE EXTRACTION ON A SMALL-SCALE [J].
JUNK, GA ;
RICHARD, JJ .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :451-454
[8]   Optimization and validation of a low temperature microwave-assisted extraction method for analysis of polycyclic aromatic hydrocarbons in airborne particulate matter [J].
Karthikeyan, S ;
Balasubramanian, R ;
See, SW .
TALANTA, 2006, 69 (01) :79-86
[9]   Determination of polycyclic aromatic hydrocarbons in precipitation using solid-phase extraction and column liquid chromatography [J].
Kiss, G ;
VargaPuchony, Z ;
Hlavay, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (02) :261-272
[10]   Qualitative and quantitative analysis of tocopherols in toothpastes and gingival tissue employing HPLC NMR and HPLC MS coupling [J].
Lienau, A ;
Glaser, T ;
Krucker, M ;
Zeeb, D ;
Ley, F ;
Curro, F ;
Albert, K .
ANALYTICAL CHEMISTRY, 2002, 74 (20) :5192-5198