Do surgical clips interfere with radiofrequency thermal ablation?

被引:18
作者
Boll, DT [1 ]
Lewin, JS [1 ]
Duerk, JL [1 ]
Merkle, EM [1 ]
机构
[1] Case Western Reserve Univ Hosp, Dept Radiol, Cleveland, OH 44106 USA
关键词
D O I
10.2214/ajr.180.6.1801557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. This study sought to evaluate whether surgical clips affect tissue conductivity and thereby alter the induction of radiofrequency ablation lesions and to determine whether therapy is safe after previous placement of clips in the liver. Materials and Methods. An ex vivo porcine hepatic model was used. Three. clips were placed around a radiofrequency electrode at 10, 20, and 30 mm from the point of insertion. Clips were arranged in a plane either perpendicular or parallel to the electrode track. After placement of the liver specimen on a grounding pad, radiofrequency energy was applied in a standardized manner for 5 min. Lesion growth and morphology were documented for each minute. Results. Radiofrequency lesions appeared circular and homogeneous after 5 min. Lesion diameter perpendicular to the radiofrequency electrode averaged 30 mm. However, lesion formation was irregular during the early phase of the radiofrequency ablation. The lesion extended irregularly toward the 1-cm clip after 60 see of ablation. During the second minute, a distinct lesion was observed around the clip 1 cm from the electrode; the primary lesion had not yet reached the clip. During the final 3 min, the primary lesion reached the 1-cm clip and ultimately incorporated the satellite lesion. No lesions were detected surrounding the more distant clips. Conclusion. Our data suggest that with the parameters applied in our study, radiofrequency ablation can be safely performed in patients with implanted clips. No aberrant conduction is observed around surgical clips that are located 20 mm and further from the radiofrequency electrode.
引用
收藏
页码:1557 / 1560
页数:4
相关论文
共 13 条
[1]  
ALLISTAIR S, 1990, MOD PHYS, P474
[2]   Calculated RF electric field and temperature distributions in RF thermal ablation: Comparison with gel experiments and liver imaging [J].
Cheng, YCN ;
Brown, RW ;
Chung, YC ;
Duerk, JL ;
Fujita, H ;
Lewin, JS ;
Schuele, DE ;
Shvartsman, S .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :70-76
[3]   Radiofrequency thermal ablation: Computer analysis of the size of the thermal injury created by overlapping ablations [J].
Dodd, GD ;
Frank, MS ;
Aribandi, M ;
Chopra, S ;
Chintapalli, KN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :777-782
[4]  
Goldberg S N, 2001, Eur J Ultrasound, V13, P129, DOI 10.1016/S0929-8266(01)00126-4
[5]  
Goldberg SN, 1996, ACAD RADIOL, V3, P636
[6]   Transluminal radiofrequency tissue ablation with use of metallic stents [J].
Goldberg, SN ;
Ryan, TP ;
Hahn, PF ;
Schima, W ;
Dawson, SL ;
Lawes, KR ;
Mueller, PR ;
Gazelle, GS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (05) :835-843
[7]   Variables affecting proper system grounding for radiofrequency ablation in an animal model [J].
Goldberg, SN ;
Solbiati, L ;
Halpern, EF ;
Gazelle, GS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (08) :1069-1075
[8]   Aneurysm clips: Effects of long-term and multiple exposures to a 1.5-T MR system [J].
Kanal, E ;
Shellock, FG .
RADIOLOGY, 1999, 210 (02) :563-565
[9]   Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility [J].
Lewin, JS ;
Connell, CF ;
Duerk, JL ;
Chung, YC ;
Clampitt, ME ;
Spisak, J ;
Gazelle, GS ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :40-47
[10]   TREATMENT OF HEPATOCELLULAR-CARCINOMA - VALUE OF PERCUTANEOUS MICROWAVE COAGULATION [J].
MURAKAMI, R ;
YOSHIMATSU, S ;
YAMASHITA, Y ;
MATSUKAWA, T ;
TAKAHASHI, M ;
SAGARA, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1159-1164