A two bead immunoassay in a micro fluidic device using a flat laser intensity profile for illumination

被引:12
作者
Roos, P
Skinner, CD
机构
[1] Montréal, PQ H3G 1M8
关键词
D O I
10.1039/b300995e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently it was demonstrated that a collimated Gaussian beam can be converted to a flattop beam using a Keplerian beam reshaper consisting of two aspheric lenses. Here, using the same optical system, we demonstrate that this flattop profile can be maintained when used in a confocal detection system that focuses the laser beam into a diameter of only 33 mum. The intensity profile of the reshaped beam was determined by imaging the excitation of a constant stream of fluorescein inside a microfluidic device. The resulting shape had a 6.38% RSD intensity across the flat profile when imaged with a CCD camera. This flat illumination profile was then used in a two bead multiplex immunoassay where the colour combination and/or the intensities can be used to determine the presence of an antigen. Detection limits of TNF-alpha and IL-6 were comparable with standard ELISA immunoassays.
引用
收藏
页码:527 / 531
页数:5
相关论文
共 19 条
[1]   Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay [J].
Carson, RT ;
Vignali, DAA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :41-52
[2]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[3]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[4]  
Dean P.N., 1998, CURRENT PROTOCOLS CY
[5]   Determination of properties of individual liposomes by capillary electrophoresis with postcolumn laser-induced fluorescence detection [J].
Duffy, CF ;
Gafoor, S ;
Richards, DP ;
Admadzadeh, H ;
O'Kennedy, R ;
Arriaga, EA .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1855-1861
[6]   Dielectrophoretic sorting of particles and cells in a microsystem [J].
Fiedler, S ;
Shirley, SG ;
Schnelle, T ;
Fuhr, G .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1909-1915
[7]  
Gunasekera N, 2002, ELECTROPHORESIS, V23, P2110, DOI 10.1002/1522-2683(200207)23:13<2110::AID-ELPS2110>3.0.CO
[8]  
2-3
[9]   High sensitivity immunoassays using particulate fluorescent labels [J].
Hall, M ;
Kazakova, I ;
Yao, YM .
ANALYTICAL BIOCHEMISTRY, 1999, 272 (02) :165-170
[10]   Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules [J].
Han, MY ;
Gao, XH ;
Su, JZ ;
Nie, S .
NATURE BIOTECHNOLOGY, 2001, 19 (07) :631-635