Early complications of pulmonary vein catheter ablation for atrial fibrillation:: A multicenter prospective registry on procedural safety

被引:160
作者
Bertaglia, Emanuele
Zoppo, Franco
Tondo, Claudio
Cotella, Andrea
Mantovan, Roberto
Senatore, Gaetano
Bottoni, Nicola
Carreras, Giovanni
Coro, Leonardo
Turco, Pietro
Mantica, Massimo
Stabile, Giuseppe
机构
[1] Dipartimento Cardiol,Osped Civil Mirano, Venice, Italy
[2] Osped San Camillo, Rome, Italy
[3] Osped Careggi, Florence, Italy
[4] Osped Ca Foncello, Treviso, Italy
[5] Osped Civil Cirie, Turin, Italy
[6] Osped Civile Santa Maria, Nuoro, Italy
[7] Osped Santa Maria Loreto, Naples, Italy
[8] Osped Civile Conegliano, Treviso, Italy
[9] Casa Cura Villa Maria Cecilia, Ravena, Italy
[10] Osped Sant Ambrogio, Milan, Italy
[11] Casa Cura San Michele, Maddaloni Caserta, Italy
关键词
atrial fibrillation; catheter ablation; complications;
D O I
10.1016/j.hrthm.2007.06.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Data on the procedural safety of pulmonary vein radiofrequency catheter ablation for atrial fibrillation (AF) are as yet scant. OBJECTIVE The aims of the present study were to prospectively evaluate the incidence of early complications of pulmonary vein ablation for AF in an unselected population of consecutive patients, and to identify possible predictors. METHODS From April 2005 to October 2006, data from 1,011 consecutive patients who were undergoing radiofrequency catheter ablation for every type of AF in 10 Italian centers were collected. All complications occurring from the admission of the patient up to the 30th day were considered. RESULTS No procedure-related death was observed. Complications occurred in 40 patients (3.9%): 12 (1.2%) had peripheral vascular complications, 8 (0.8%) had conservatively treated pericardial effusion, 6 (0.6%) had cardiac tamponade (successfully drained), 5 (0.5%) had cerebral embolisms, 4 (0.4%) presented pulmonary vein stenosis >50%, and 5 (0.5%) presented other isolated adverse events. History of coronary artery disease (odds ratio 5,603, 95% confidence interval 1,559 to 20,139, P <.008) characterized patients who presented with hemorrhagic complications. CONCLUSION Early complications of pulmonary vein catheter ablation seem to be fewer than in the early years of AF ablation, but still occur in 3.9% of procedures.
引用
收藏
页码:1265 / 1271
页数:7
相关论文
共 22 条
[1]   Discrepancies between catheter tip and tissue temperature in cooled-tip ablation - Relevance to guiding left atrial ablation [J].
Bruce, GK ;
Bunch, TJ ;
Milton, MA ;
Sarabanda, A ;
Johnson, SB ;
Packer, DL .
CIRCULATION, 2005, 112 (07) :954-960
[2]   Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation [J].
Cappato, R ;
Calkins, H ;
Chen, SA ;
Davies, W ;
Iesaka, Y ;
Kalman, J ;
Kim, YH ;
Klein, G ;
Packer, D ;
Skanes, A .
CIRCULATION, 2005, 111 (09) :1100-1105
[3]   Comparison of cool tip versus 8-mm tip catheter in achieving electrical isolation of pulmonary veins for long-term control of atrial fibrillation: A prospective randomized pilot study [J].
Dixit, Sanjay ;
Gerstenfeld, Edward P. ;
Callans, David J. ;
Cooper, Joshua M. ;
Lin, David ;
Russo, Andrea M. ;
Verdino, Ralph J. ;
Patel, Vickas V. ;
Kimmel, Stephen E. ;
Ratcliffe, Sarah J. ;
Hsia, Henry H. ;
Nayak, Hemal M. ;
Zado, Erica ;
Ren, Jian-Fang ;
Marchlinski, Francis E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (10) :1074-1079
[4]   ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
CIRCULATION, 2006, 114 (07) :E257-E354
[5]   THE MULTICENTER-EUROPEAN-RADIOFREQUENCY-SURVEY (MERFS) - COMPLICATIONS OF RADIOFREQUENCY CATHETER ABLATION OF ARRHYTHMIAS [J].
HINDRICKS, G ;
ALIOT, E ;
ALMENDRAL, JM ;
AMLIE, J ;
ARLOTTI, M ;
BARNAY, C ;
BASHIR, Y ;
BERGFELDT, L ;
BLANC, J ;
HIMBERT, J ;
THOMSEN, PEB ;
BLOMSTROMLUNDQVIST, C ;
BREMBILLAPERROT, B ;
BRUGADA, P ;
BRUGADA, J ;
COWAN, JC ;
CAUCHEMEZ, B ;
CLEMENTY, J ;
COBBE, S ;
CRITELLI, G ;
CRIJNS, H ;
DAUBERT, JC ;
DESOUSA, J ;
DJIANE, P ;
DONZEAU, JP ;
DUCKECK, W ;
EDWARDSSON, N ;
FARRE, J ;
COSNAY, P ;
FONTAINE, G ;
FROMER, M ;
GOICOLEA, A ;
GONSKA, BD ;
GROLLEAURAOUX, R ;
HAISSAGUERRE, M ;
HAVERKAMP, W ;
HERMIDA, JS ;
HIEF, C ;
HOPP, HW ;
HOFFMAN, E ;
HUIKURI, H ;
JORDAENS, L ;
KALUSCHE, D ;
KUHLKAMP, V ;
LAUCEVICIUS, A ;
LAVERGNE, T ;
MANZ, M ;
MOLLER, M ;
MONT, L ;
NATHAN, AW .
EUROPEAN HEART JOURNAL, 1993, 14 (12) :1644-1653
[6]  
INAMA G, 2003, G ITAL ARITMOL CARDI, V4, P237
[7]   Catheter ablation for atrial fibrillation [J].
Jais, P ;
Sanders, P ;
Hsu, LF ;
Hocini, M ;
Haissaguerre, M .
HEART, 2005, 91 (01) :7-9
[8]   Stepwise catheter ablation of chronic atrial fibrillation:: Importance of discrete anatomic sites for termination [J].
Jais, Pierre ;
O'Neill, Mark D. ;
Takahashi, Yoshihide ;
Jonsson, Anders ;
Hocini, Meleze ;
Sacher, Frederic ;
Sanders, Prashanthan ;
Kodali, Sathish ;
Rostock, Thomas ;
Rotter, Martin ;
Clementy, Jacques ;
Haissaguerre, Michel .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 :S28-S36
[9]   Thrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation? [J].
Lee, DSY ;
Dorian, P ;
Downar, E ;
Burns, M ;
Yeo, EL ;
Gold, WL ;
Paquette, M ;
Lau, W ;
Newman, DM .
EUROPACE, 2001, 3 (03) :195-200
[10]   A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate [J].
Nademanee, K ;
McKenzie, J ;
Kosar, E ;
Schwab, M ;
Sunsaneewitayakul, B ;
Vasavakul, T ;
Khunnawat, C ;
Ngarmukos, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2044-2053