Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist

被引:18
作者
Wakisaka, Y
Okuzono, Y
Taenaka, Y
Chikanari, K
Endo, S
Masuzawa, T
Takano, H
机构
[1] Toyobo Co Ltd, Med Equipment & Device Prod Res Ctr, Osaka, Japan
[2] Natl Cardiovasc Ctr, Inst Res, Dept Artificial Organs, Osaka, Japan
关键词
flow rate estimation; flow control; nonpulsatile pump; energy consumption; blood temperature;
D O I
10.1046/j.1525-1594.1998.06130.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A bypass now rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated now rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and body temperature. The error in the EF was 0.5 +/- 0.4 L/min in in vivo experiments for 40 days. The rotating speed of the motor was controlled automatically every 200 ms to bring the EF in accord with the desired flow rate (DF). The reactivity and accuracy of the BECS were Investigated in in vitro and in vivo experiments. The ICBP was operated by the BECS in a mock circuit in parallel with a pulsatile ventricular assist device (PVAD) to simulate left heart bypass. The reactivity was evaluated by changing the DF from 7 L/min to 5 L/min at an afterload of 160/97 mm Hg. To evaluate the accuracy of the BECS, the ICBP was driven under the aortic pressure of 110/85 mm Hg in the abdominal wall of an adult goal (70 kg). The DF was set at 5 L/min for 4 min for the goal in an awake condition. II took 13 s to change the flow rate in the in vitro experiment. The measured flow rate (MF) was maintained at 5.0 +/- 0.2 L/min by the BECS in vivo. In conclusion, the BECS has moderate reactivity and accuracy.
引用
收藏
页码:488 / 492
页数:5
相关论文
共 7 条
[1]   IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM [J].
FRAZIER, OH ;
ROSE, EA ;
MCCARTHY, P ;
BURTON, NA ;
TECTOR, A ;
LEVIN, H ;
KAYNE, HL ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF SURGERY, 1995, 222 (03) :327-338
[2]   SYSTEM CONSIDERATIONS FAVORING ROTARY ARTIFICIAL HEARTS WITH BLOOD-IMMERSED BEARINGS [J].
JARVIK, RK .
ARTIFICIAL ORGANS, 1995, 19 (07) :565-570
[3]  
NAKATANI T, 1995, ASAIO J, V41, pM562
[4]   Development and initial testing of a permanently implantable centrifugal pump [J].
Nakazawa, T ;
Takami, Y ;
Benkowski, R ;
Ohtsubo, S ;
Yukio, O ;
Tayama, E ;
Ohtsuka, G ;
Niimi, Y ;
Glueck, J ;
Sueoka, A ;
Schmallegger, H ;
Schima, H ;
Wolner, E ;
Nose, Y .
ARTIFICIAL ORGANS, 1997, 21 (07) :597-601
[5]   A MINIATURE HYBRID REFLECTION TYPE OPTICAL SENSOR FOR MEASUREMENT OF HEMOGLOBIN CONTENT AND OXYGEN-SATURATION OF WHOLE-BLOOD [J].
TAKATANI, S ;
NODA, H ;
TAKANO, H ;
AKUTSU, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (03) :187-198
[6]  
WAKISAKA Y, 1997, IN PRESS ASAIO J
[7]  
WAKISAKA Y, 1997, IN PRESS ARTIF ORGAN