Hybrid total hip arthroplasty in patients under the age of fifty - A five- to ten-year follow-up

被引:43
作者
Sporer, SM [1 ]
Callaghan, JJ [1 ]
Olejniczak, JP [1 ]
Goetz, DD [1 ]
Johnston, RC [1 ]
机构
[1] Iowa Methodist Med Ctr, Des Moines, IA USA
关键词
hybrid; arthroplasty; hip; young; fifty;
D O I
10.1016/S0883-5403(98)90045-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In 37 patients, 45 total hip replacements were performed using contemporary cementing techniques, an uncemented Harris-Galante I acetabular component and a cemented precoated Iowa femoral component in patients under the age of 50 at the time of their surgery; 36 patients with 43 :hybrid flips were living, 1 patient with 2 hybrid hips was decreased. No patients were lost to follow-up. At 5- to 10-year follow-up, eight hips were revised for aseptic loosening. No acetabular components, and eight femoral components (18%) were revised for aseptic loosening. When looking at radiographic results, including revision as well as those components that were probably or definitely loose on radiographs, 0 acetabular components and 11 femoral components (24%) were radiographically loose. These results demonstrate the excellent durability of the uncemented Harris-Galante acetabular component in the younger patient. However, the Iowa grit-blasted methyl methacrylate precoated femoral component had a magnitude increase in the prevalence of revision for aseptic femoral loosening when compared to the senior author's long-term Charnley results in this age group. The authors attribute the failure to the rough surface finish applied to the femoral component. However, the polymethyl methacrylate proximal precoating and the femoral component design may also contribute to the femoral failures.
引用
收藏
页码:485 / 491
页数:7
相关论文
共 25 条
[1]   LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[2]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]  
Callaghan JJ, 1996, CLIN ORTHOP RELAT R, P118
[4]  
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, P14
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]   EARLY AND LATE LOOSENING OF THE ACETABULAR CUP AFTER LOW-FRICTION ARTHROPLASTY [J].
GARCIACIMBRELO, E ;
MUNUERA, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08) :1119-1129
[7]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[8]  
HARRIS WH, 1983, CLIN ORTHOP RELAT R, P7
[9]   LOOSENING OF THE FEMORAL COMPONENT AFTER USE OF THE MEDULLARY-PLUG CEMENTING TECHNIQUE - FOLLOW-UP NOTE WITH A MINIMUM 5-YEAR FOLLOW-UP [J].
HARRIS, WH ;
MCGANN, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1064-1066
[10]  
HARRIS WH, 1989, CLIN ORTHOPAEDICS, V249, P212