Harmonic pollution has been serious in recent years. Passive filters have been used to suppress harmonic current conventionally. However, passive power filters have the problem of resonance. To solve the resonance problem, active power filters and hybrid power filters were developed. After considering the power capacity and cost, the hybrid power filter is the better choice for the future. Many passive power filters have already been installed in the industry power systems. However, the elements of these passive power filters are often destroyed due to the resonance or the harmonic current injection of a neighbouring harmonic source. To improve the performance of passive power filters, a small capacity of hybrid power filler is proposed to connect in parallel with the existing passive power filters. The combined power filter system, which contains the parallel operation of existing passive power filters and hybrid power filters. is analysed and simulated. The simulation results show that the filter performance and resonance problem of existing passive power filters can be improved by applying the hybrid power filter.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 11 条
[1]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[2]   Hybrid solutions for improving passive filter performance in high power applications [J].
Bhattacharya, S ;
Cheng, PT ;
Divan, DM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :732-747
[3]   A PRACTICAL APPROACH TO HARMONIC COMPENSATION IN POWER-SYSTEMS - SERIES CONNECTION OF PASSIVE AND ACTIVE-FILTERS [J].
FUJITA, H ;
AKAGI, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (06) :1020-1025
[4]   DESIGN OF FILTERS TO REDUCE HARMONIC DISTORTION IN INDUSTRIAL-POWER SYSTEMS [J].
GONZALEZ, DA ;
MCCALL, JC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1987, 23 (03) :504-511
[5]   SURVEY OF ACTIVE POWER-LINE CONDITIONING METHODOLOGIES [J].
GRADY, WM ;
SAMOTYJ, MJ ;
NOYOLA, AH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) :1536-1542
[6]   HARMONICS - THE EFFECTS ON POWER QUALITY AND TRANSFORMERS [J].
HENDERSON, RD ;
ROSE, PJ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (03) :528-532
[7]  
Jung GH, 1998, IEEE POWER ELECTRON, P217, DOI 10.1109/PESC.1998.701902
[8]  
PENG FZ, 1993, IEEE T IA, V29, P732
[9]   A review of active filters for power quality improvement [J].
Singh, B ;
Al-Haddad, K ;
Chandra, A .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (05) :960-971
[10]   Investigation and mitigation of harmonic amplification problems caused by single-tuned filters [J].
Wu, CJ ;
Chiang, JC ;
Yen, SS ;
Liao, CJ ;
Yang, JS ;
Guo, TY .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) :800-806