Single-session magnetic resonance coronary angiography and myocardial perfusion imaging using the new blood pool compound B-22956 (gadocoletic acid) -: Initial experience in a porcine model of coronary artery disease

被引:13
作者
Zheng, J
Li, DB
Maggioni, F
Abendschein, D
Simonetti, O
Laub, G
Finn, JP
Gropler, RJ
Cavagna, FM
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Northwestern Univ, Chicago, IL 60611 USA
[3] Bracco Imaging SpA, Milan, Italy
[4] Siemens Med Solut, Chicago, IL USA
[5] Univ Calif Los Angeles, Los Angeles, CA 90024 USA
关键词
cardiac MRI; myocardial perfusion; coronary artery angiography; blood pool contrast agent; animal study;
D O I
10.1097/01.rli.0000174578.51744.7d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to evaluate a new blood pool contrast agent, B-22956, for detecting myocardial perfusion abnormality and coronary artery stenosis by magnetic resonance imaging (MRI) in 1 setting. Materials and Methods: Coronary artery atherosclerotic stenoses were created in 6 miniswine. Myocardial first-pass perfusion imaging was performed with a bolus injection of 0.015 mmol/kg B-22956 during pharmacologic stress followed by postcontrast coronary artery imaging after another injection of B-22956/1. The total doses for the 6 pigs were 0.1 mmol/kg (n = 3) and 0.15 mmol/kg (n = 3). Perfusion upslope maps were analyzed and MR coronary artery images were reviewed by 2 readers. Results: For all 6 pigs, the normalized upslopes of the perfusion curves were 0.83 +/- 0.12, 0.74 +/- 0.15, and 0.52 +/- 0.05 (P < 0.01 vs. normal) with normal or mild (< 50% area stenosis), moderate (< 50% and < 75%), and severe stenosis (> 75%), respectively. Mean signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in right coronary artery images improved 90% and 200%, respectively, with a total dose of 0.1 mmol/kg of B-22956. Excellent agreements (kappa = 0.82) were achieved for evaluating the grade of stenosis between MR postcontrast coronary artery images and histopathology by 2 reviewers. Conclusion: The MR blood pool contrast agent B-22956 demonstrated the ability for detecting myocardial perfusion abnormalities and coronary artery stenosis in 1 setting.
引用
收藏
页码:604 / 613
页数:10
相关论文
共 45 条
[1]   Prolonged procoagulant activity on overstretch-injured coronary arteries in pigs [J].
Abendschein, DR ;
Yang, LY ;
Chun, J ;
Cho, D ;
Scherrer, D ;
St Pierre, J .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (04) :836-842
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[4]   A closed-chest pulmonary artery occlusion/reperfusion model in the pig -: Detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging [J].
Amundsen, T ;
Kværness, J ;
Aadahl, P ;
Waage, A ;
Bjermer, L ;
Odegård, A ;
Haraldseth, O .
INVESTIGATIVE RADIOLOGY, 2000, 35 (05) :295-303
[5]  
CAVAGNA FM, 2002, P INT SOC MAG RESON, V10, P114
[6]  
CAVAGNA FM, 1999, J CARDIOV MAGN RESON, V1, P387
[7]  
CAVAGNA FM, 2001, P INT SOC MAGN RESON, V9, P519
[8]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[9]   Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent [J].
Dewey, M ;
Kaufels, N ;
Laule, M ;
Schnorr, J ;
Raynaud, JS ;
Hamm, B ;
Taupitz, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (08) :498-505
[10]   Improved MR coronary angiography with use of a new rapid clearance blood pool contrast agent in pigs [J].
Dirksen, MS ;
Lamb, HJ ;
Kunz, P ;
Robert, P ;
Corot, C ;
de Roos, A .
RADIOLOGY, 2003, 227 (03) :802-808