A study of trace element behaviour in two modern coal-fired power plants - II. Trace element balances in two plants equipped with semi-dry flue gas desulphurisation facilities

被引:41
作者
Aunela-Tapola, L
Hatanpaa, E
Hoffren, H
Laitinen, T
Larjava, K
Rasila, P
Tolvanen, M
机构
[1] VTT Mfg Technol, FIN-02044 VTT, Finland
[2] VTT Chem Technol, FIN-02044 VTT, Finland
[3] Imatran Voima Oy, Environm Engn Lab, FIN-01019 IVO, Finland
[4] Helsinki Energy, Chem Lab, FIN-00101 Helsinki, Finland
关键词
trace elements; coal-fired power plants; desulphurisation;
D O I
10.1016/S0378-3820(97)00053-2
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Two Finnish coal-fired power plants were experimentally investigated with regard to the distribution of environmentally harmful trace elements in the process. The plants were equipped with low NOx burners, an electrostatic precipitator and a semi-dry flue gas desulphurisation unit consisting of a spray-dryer-type reactor and a fabric tilter. All the in-going and out-going mass streams were analysed for As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se and Tl in the first plant, and for As, Be, Cd, Cr, Hg, Mn, Ni, Pb, Tl and Zn in the other plant. Total atmospheric emissions of trace elements from the plants studied were very low; most of them even orders of magnitudes smaller than 10 mu g/m(3) (NTP). The vaporous fraction of the trace elements was found to play a predominant role in the atmospheric emissions. However, the total atmospheric emissions of even the strongly volatile Hg were very low, which can be ascribed to the applied plant technology. Enrichment of the elements into the various ash streams-from the bottom ash up to the particulates downstream of the electrostatic precipitator-was found to be in satisfactory compliance with literature data. Element balances were calculated over the whole process and over the desulphurisation unit for both plants: for the whole process the closure (i.e., ratio output/input) of element balances was within +/-30% for all elements studied, except for chromium in plant HE, and for the vast majority of elements it was even within +/-20%. The results imply that the sampling techniques and analytical methods developed for this work can be well applied to quantitative mass balance studies in this kind of processes. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 34
页数:22
相关论文
共 19 条
[1]  
BRONDI M, 1991, 8 INT C HEAV MET ENV, P236
[2]  
CHU P, 1993, 2 INT C MAN HAZ AIR
[3]  
CLARKE LB, 1992, IAEACR49 IEA COAL RE
[4]   DETERMINATION OF MERCURY EMISSIONS FROM A MUNICIPAL INCINERATOR [J].
DUMAREY, R ;
HEINDRYCKX, R ;
DAMS, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (02) :206-209
[5]  
GUTBERLET H, 1984, ENV492DB VEBA KRAFTW
[6]  
HATANPAA E, INPRESS FUEL PROCESS
[7]  
Kaakinen JW, 1975, ENVIRON SCI TECHNOL, V9, P862, DOI [10.1021/es60107a012, DOI 10.1021/ES60107A012]
[8]  
KAMM K, 1986, STAUB REINHALT LUFT, V46, P116
[9]   PATHWAYS OF 37 TRACE-ELEMENTS THROUGH COAL-FIRED POWER-PLANT [J].
KLEIN, DH ;
ANDREN, AW ;
CARTER, JA ;
EMERY, JF ;
FELDMAN, C ;
FULKERSON, W ;
LYON, WS ;
OGLE, JC ;
TALMI, Y ;
VANHOOK, RI ;
BOLTON, N .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1975, 9 (10) :973-979
[10]  
Laitinen T, 1996, FRESEN J ANAL CHEM, V354, P436